AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > TERMINALS OF ECU |
| CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |

Disconnect the A14 amplifier connector.
Measure the voltage and resistance of the wire harness side connector.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| IG+ (A14-10) - GND (A14-18) | R-L - L | Power source (IG) | Ignition switch OFF | Below 1 V |
| IG+ (A14-10) - GND (A14-18) | R-L - L | Power source (IG) | Ignition switch ON | 10 to 14 V |
| GND (A14-18) - Body ground | L - Body ground | Ground | Always | Below 1 Ω |
| ACON (A14-4) - GND (A14-18) | R-G - L | A/C switch signal | Ignition switch START Blower switch ON A/C switch OFF | Below 1 V |
| ACON (A14-4) - GND (A14-18) | R-G - L | A/C switch signal | Ignition switch START Blower switch ON A/C switch ON | 10 to 14 V |
| IND- (A14-13) - GND (A14-18) | R-L - L | A/C indicator light signal | Ignition switch START Blower switch ON A/C switch OFF | Below 1 V |
| IND- (A14-13) - GND (A14-18) | R-L - L | A/C indicator light signal | Ignition switch START Blower switch ON A/C switch ON | 10 to 14 V |
Reconnect the A14 amplifier connector.
Measure the voltage and resistance of the connector.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| PSW (A14-3) - GND (A14-18) | Y-B - L | A/C pressure switch signal | Ignition switch START Refrigerant pressure normal: 0.18 MPa (1.9 kgf/cm2, 26 psi) to 3.03 MPa (31.0 kgf/cm2, 440 psi) A/C switch ON Blower switch ON | 10 to 14 V |
| PSW (A14-3) - GND (A14-18) | Y-B - L | A/C pressure switch signal | Ignition switch START Refrigerant pressure less than: 0.18 MPa (1.9 kgf/cm2, 26 psi) or more than 3.03 MPa (31.0 kgf/cm2, 440 psi) A/C switch ON Blower switch ON | Below 1 V |
| TE (A14-7) - SG-1 (A14-8) | G - P | A/C evaporator temperature sensor signal | Ignition switch ON Evaporator temperature is 0°C (32°F) Temperature control knob: MAX COOL | 2.0 to 2.4 V |
| TE (A14-7) - SG-1 (A14-8) | G - P | A/C evaporator temperature sensor signal | Ignition switch ON Evaporator temperature is 15°C (59°F) Temperature control knob: MAX COOL | 1.4 to 1.8 V |
| SG1-1 (A14-8) - Body ground | P-L | Ground for A/C evaporator temperature sensor | Always | Below 1 Ω |
| MGC (A14-1) - GND (A14-18) | L-W - L | Magnet clutch signal | Ignition switch START Magnet clutch is not engaged | Below 1 V |
| MGC (A14-1) - GND (A14-18) | L-W - L | Magnet clutch signal | Ignition switch START Magnet clutch is engaged | 10 to 14 V |
| ACT (A14-2) - GND (A14-18) | R-L - L | Magnet on permit signal | Ignition switch START A/C switch OFF Blower switch ON | Below 1 V |
| ACT (A14-2) - GND (A14-18) | R-L - L | Magnet on permit signal | Ignition switch START A/C switch ON Blower switch ON | 10 to 14 V |
| AC1 (A14-14) - GND (A14-18) | Y - L | Idle-up request signal | Ignition switch START Magnet clutch is not engaged | 10 to 14 V |
| AC1 (A14-14) - GND (A14-18) | Y - L | Idle-up request signal | Ignition switch START Magnet clutch is engaged | Below 1 V |