Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > IG Power Source Circuit

for Preparation Click here


DESCRIPTION

The main power source is supplied to the air conditioning amplifier assembly when the ignition switch is turned to on. The power source is used for operating the air conditioning amplifier assembly, servo motors, etc.

WIRING DIAGRAM


E227739E03


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY AND BODY GROUND)


    E170963E29
  1. Disconnect the A38 air conditioning amplifier assembly connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A38-6 (IG+) - Body ground
    Ignition switch off
    Below 1 V
    Ignition switch ON
    11 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A38-1 (GND) - Body ground
    Always
    Below 1 Ω

Text in Illustration 
*a
Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)