Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › SOLAR SENSOR (for Automatic Air Conditioning System)

SOLAR SENSOR (for Automatic Air Conditioning System) > INSPECTION

for Preparation Click here



1. INSPECT SOLAR SENSOR


E170951E10
  1. Connect the connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Sensor not exposed to sunlight or inspection light
    Below 0.8 V
    Sensor exposed to sunlight or inspection light
    0.8 to 4.3 V

    HINT:
    1. Check from the rear of the connector while it is connected to the cooler thermistor (solar sensor).
    2. Use an incandescent light for inspection. Bring it within 30 cm (11.8 in.) of the cooler thermistor (solar sensor).

    If the result is not as specified, replace the cooler thermistor (solar sensor).
    Text in Illustration 
    *a
    Component with harness connected
    (Cooler Thermistor (Solar Sensor))