2KD-FTV INTAKE > SERVICE DATA |
| Vacuum switching valve (for Swirl Control Valve) | Standard resistance | Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 33 to 39 Ω | ||
| 1 - Body ground | 20°C (68°F) | 10 kΩ or higher | ||
| 2 - Body ground |
| Turbocharger pressure | Condition | Specified Condition |
| Engine speed (approximately 4600 rpm) | 10 to 40 kPa (0.10 to 0.41 kgf/cm2, 1.5 to 5.8 psi) | |
| Axial play of turbine shaft | Maximum axial play | 0.11 mm (0.00433 in.) |