1. INSPECT COUNTER GEAR
Using a micrometer, measure the journal diameter.
Standard diameter:
25.984 to 26.000 mm (1.0230 to 1.0236 in.)
Minimum diameter:
25.984 mm (1.0230 in.)
If the diameter is less than the minimum, replace the counter gear.