Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › BLOWER UNIT (for Automatic Air Conditioning System)

BLOWER UNIT (for Automatic Air Conditioning System) > DISASSEMBLY

for Preparation Click here



1. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY


    E225627
  1. Remove the 3 screws and recirculation damper servo sub-assembly.



2. REMOVE CLEAN AIR FILTER


E225195
  1. Detach the claw and remove the air filter case.

  1. Remove the clean air filter.



3. REMOVE BLOWER MOTOR CONTROL


E233808
  1. Remove the 2 screws and blower motor control.



4. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY


E233172
  1. Remove the 3 screws and blower motor with fan sub-assembly.