Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › BLOWER UNIT (for Automatic Air Conditioning System)

BLOWER UNIT (for Automatic Air Conditioning System) > REASSEMBLY

for Preparation Click here



1. INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY
  1. Install the blower motor with fan sub-assembly with 3 bolts.



2. INSTALL BLOWER MOTOR CONTROL
  1. Install the blower motor control with 2 screws.



3. INSTALL CLEAN AIR FILTER
  1. Install the clean air filter.

  1. Attach the claw to install the air filter case.



4. INSTALL RECIRCULATION DAMPER SERVO SUB-ASSEMBLY
  1. Install the recirculation damper servo sub-assembly with 3 screws.

  1. Attach the claw to install the recirculation damper servo sub-assembly.