P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2)
Diagnostic trouble codes · Vehicles built from Aug 2012
Also covers:
- P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2)
- P0057 Oxygen Sensor Heater Control Circuit Low (Bank 2 Sensor 2)
- P0058 Oxygen Sensor Heater Control Circuit High (Bank 2 Sensor 2)
Versions by build date: Jun 2011 – Jul 2012 from Aug 2012
DESCRIPTION
- Refer to DTC P0136 (Click here).
- HINT:
- When any of these DTCs are set, the ECM enters fail-safe mode. The ECM turns off the heated oxygen sensor (HO2S) heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned OFF.
- The ECM uses a pulse width modulated control circuit to adjust current through the heater. The heated oxygen sensor heater circuit uses a relay on the +B side of the circuit.
- When any of these DTCs are set, the ECM enters fail-safe mode. The ECM turns off the heated oxygen sensor (HO2S) heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned OFF.
-


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0037 P0057 |
Heated oxygen sensor (HO2S) heater current less than 0.3 A (1 trip detection logic) |
|
| P0038 P0058 |
Heated oxygen sensor (HO2S) heater current more than 2 A (1 trip detection logic) |
|
- HINT:
- Bank 1 refers to the bank that includes the No. 1 cylinder.
- Bank 2 refers to the bank that does not include the No. 1 cylinder.
- Sensor 1 refers to the sensor closer to the engine assembly.
- Sensor 2 refers to the sensor farther away from the engine assembly.
- Bank 1 refers to the bank that includes the No. 1 cylinder.
MONITOR DESCRIPTION
- The sensing portion of the heated oxygen sensor has a zirconia element which is used to detect oxygen concentration in the exhaust. If the zirconia element is at the appropriate temperature and the difference of the oxygen concentrations between the inside and outside surface of the sensor is large, the zirconia element will generate voltage signals. In order to increase the oxygen concentration detecting capacity of the zirconia element, the ECM supplements the heat from the exhaust with the heat from the heating element inside the sensor. When the current in the sensor is out of the standard operating range, the ECM interprets this as a fault in the heated oxygen sensor heater and sets a DTC.
- Example:
- The ECM will set a high current DTC if the current in the sensor is more than 2 A when the heater is OFF. Similarly, the ECM will set a low current DTC if the current is less than 0.3 A when the heater is ON.
WIRING DIAGRAM
Refer to DTC P0136 (Click here).INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
- Sensor 1 refers to the sensor mounted before the Three-Way Catalytic Converter (TWC) and is located near the engine assembly.
- Sensor 2 refers to the sensor mounted after the TWC and is located far from the engine assembly.
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
| 1. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
![]() ![]() |
Disconnect the heated oxygen sensor connector.
Measure the resistance of the sensor.
- Standard resistance (Bank 1 Sensor 2):
Tester Connection
Condition
Specified Condition
1 (HT1B) - 2 (+B)
20°C (68°F)
10 to 17 Ω
1 (HT1B) - 4 (E2)
-
10 kΩ or higher
- Standard resistance (Bank 2 Sensor 2):
Tester Connection
Condition
Specified Condition
1 (HT2B) - 2 (+B)
20°C (68°F)
10 to 17 Ω
1 (HT2B) - 4 (E2)
-
10 kΩ or higher
|
|
||||
| OK | |
| 2. INSPECT INTEGRATION NO.1 RELAY (MAIN RELAY) |
![]() ![]() |
Disconnect the integration relay from the engine room junction block.
Measure the voltage of the MAIN relay.
- Standard voltage:
Tester Connection
Condition
Specified Condition
1J-5 - Body ground
Ignition switch ON
10 to 14 V
|
|
||||
| OK | |
| 3. INSPECT ECM (HT1B AND HT2B VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the ECM connector.
- Standard voltage:
Tester Connection
Specified Condition
E15-1 (HT1B) - E17-1 (E1)
9 to 14 V
E16-5 (HT2B) - E17-1 (E1)
9 to 14 V
|
|
||||
| NG | |
| 4. CHECK WIRE HARNESS (HEATED OXYGEN SENSOR - ECM, HEATED OXYGEN SENSOR - INTEGRATION RELAY) |
![]() ![]() |
Disconnect the H7 or H8 sensor connector.
Disconnect the E15 or E16 ECM connector.
Disconnect the 1J connector from the engine room junction block.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Bank 1 Sensor 2):
Tester Connection
Specified Condition
H7-1 (HT1B) - E15-1 (HT1B)
Below 1 Ω
H7-2 (+B) - 1J-5
Below 1 Ω
H7-1 (HT1B) or E15-1 (HT1B) - Body ground
10 kΩ or higher
H7-2 (+B) or 1J-5 - Body ground
10 kΩ or higher
- Standard resistance (Bank 2 Sensor 2):
Tester Connection
Specified Condition
H8-1 (HT2B) - E16-5 (HT2B)
Below 1 Ω
H8-2 (+B) - 1J-5
Below 1 Ω
H8-1 (HT2B) or E16-5 (HT2B) - Body ground
10 kΩ or higher
H8-2 (+B) or 1J-5 - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||




