Starter Signal Circuit
Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
While the engine is being cranked, current flows from terminal ST2 of the ignition switch to the ST fuse and also flows to terminal STA of the ECM (STA Signal).WIRING DIAGRAM
Refer to DTC P0617 (Click here).INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- HINT:
- This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table (Click here).
| 1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Read the value.
- OK:
Ignition Switch Condition
Starter Signal
ON
OFF
START
ON
|
|
||||
| OK | ||
| ||
| 2. CHECK HARNESS AND CONNECTOR (STARTER RELAY [ST] - ECM) |
Remove the starter relay (ST) from the engine room relay block and junction block assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
ST relay terminal 1 - E31-6 (STA)
Always
Below 1 Ω
ST relay terminal 1 or E31-6 (STA) - Body ground
Always
10 kΩ or higher
Reinstall the starter relay (ST).
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||