Apply a light coat of engine oil to the O-ring of the sensor.
Install the sensor with the bolt.
Torque:
8.5 N*m{
87 kgf*cm
, 75 in.*lbf
}
Install the connector to the connector bracket.
Attach the harness clamp.
Connect the sensor connector.
2.
INSTALL NO. 1 COMPRESSOR MOUNTING BRACKET
NOTICE:
Install the No. 1 compressor mounting bracket exactly as described in the procedures below to properly secure and prevent damage to the fan and generator V belt.
Temporarily install the No. 1 compressor mounting bracket with the 3 bolts.
HINT:
Temporarily install the No. 1 compressor mounting bracket with the 3 bolts so that the bracket can be moved by hand.
Push the No. 1 compressor mounting bracket toward the cylinder block as shown in the illustration and tighten bolt B.
Torque:
45 N*m{
459 kgf*cm
, 33 ft.*lbf
}
for bolt B
HINT:
Make sure there is no clearance between the cylinder block and No. 1 compressor mounting bracket as shown in the illustration.
Uniformly tighten the 4 bolts in the order shown in the illustration.
Torque:
45 N*m{
459 kgf*cm
, 33 ft.*lbf
}
for bolt A
24.5 N*m{
250 kgf*cm
, 18 ft.*lbf
}
for bolt C
3.
INSTALL COOLER COMPRESSOR ASSEMBLY
Temporarily install the compressor with the bolt labeled A.
Install the compressor completely by tightening the 4 bolts in the order shown in the illustration.
Torque:
25 N*m{
255 kgf*cm
, 18 ft.*lbf
}
NOTICE:
In order to prevent misalignment, which causes belt rattle, tightening of the bolts must be performed in the order shown.
Connect the compressor connector.
Install the suction hose with the 2 bolts.
Torque:
5.4 N*m{
55 kgf*cm
, 48 in.*lbf
}
4.
INSTALL DRIVE BELT
Install the drive belt to the pulleys except the drive belt tensioner pulley.
Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward and then install the drive belt to the tensioner pulley.
NOTICE:
The backside of the drive belt should face the tensioner pulley.
Check that the drive belt is properly set to each pulley.
After a new belt has been installed, check that the tensioner indicator mark is within range A shown in the illustration.