P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)
Diagnostic trouble codes · Vehicles built from Aug 2012
Also covers:
- P0974 Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)
DESCRIPTION
Shifting from 1st to 4th is performed in combination with the on and off operation of shift solenoid valves S1 and S2, which are controlled by the TCM. If an open or short circuit occurs in either of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely. Also, the TCM stops sending current to the open or short-circuited solenoid (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P0973 |
TCM detects a short in the solenoid valve S1 circuit 4 times when solenoid valve S1 is operated (1-trip detection logic). |
|
| P0974 |
TCM detects an open in the solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated (1-trip detection logic). |
|
MONITOR DESCRIPTION
These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in either shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve S1 is on, if its resistance is 8 Ω or less, the TCM determines there is a short in the shift solenoid valve S1 circuit.When shift solenoid valve S1 is off, if its resistance is 100 kΩ or higher, the TCM determines there is an open in the shift solenoid valve S1 circuit (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1) |
Disconnect the transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
4 (S1) - Body ground
20°C (68°F)
11 to 15 Ω
Text in Illustration *a
Component without harness connected
(Transmission Wire)
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
Disconnect the TCM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
T19-18 (S1) - Body ground
20°C (68°F)
11 to 15 Ω
Text in Illustration *a
Rear view of wire harness connector
(to TCM)
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE S1 |
Remove shift solenoid valve S1.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body
20°C (68°F)
11 to 15 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) → Shift solenoid valve S1 connector
- Battery negative (-) → Shift solenoid valve S1 body
Valve moves and makes an operating noise
- Battery positive (+) → Shift solenoid valve S1 connector
| *a |
Component without harness connected (Shift Solenoid Valve S1) |
|
|
||||
| OK | ||
| ||