P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built Jun 2011 – Jul 2012
Versions by build date: Jun 2011 – Jul 2012 from Aug 2012
DESCRIPTION
Refer to DTC P2714 (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P2716 |
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic) |
|
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
Disconnect the E1 wire connector.

Measure the resistance of the wire connector.
- Standard resistance:
Tester Connection
Condition
Specified Condition
14 (SLT+) - 6 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
14 (SLT+) - Body ground
20°C (68°F)
10 kΩ or higher
6 (SLT-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
Disconnect the E16 ECM connector.

Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E16-13 (SLT+) - E16-12 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
E16-13 (SLT+) - Body ground
20°C (68°F)
10 kΩ or higher
E16-12 (SLT-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLT |
![]() ![]() |
Remove the shift solenoid valve SLT.
Measure the resistance of the solenoid valve.
- Standard resistance:
- 5.0 to 5.6 Ω at 20°C (68°F)
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
Check the operating noise of the solenoid valve.
- OK:
- Solenoid makes operating noise.
- HINT:
-


- Reference: Inspect using an oscilloscope.
- Check the waveform of the ECM connector.
- OK:
- Refer to illustration.
Item
Content
Tester Connection
E16-13 (SLT+) - E16-12 (SLT-)
Tool Setting
5 V/DIV., 1 msec./DIV.
Condition
Engine is idling
|
|
||||
| OK | ||
| ||