P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)
Diagnostic trouble codes · Vehicles built from Jun 2011
DESCRIPTION
Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the ECM. If an open or short circuit occurs in the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P0748 |
ECM checks for an open or short in shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic) Output signal duty equal to 100%
|
|
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the circuit.While driving and shifting between 4th and 5th gears, if the ECM detects an open or short in the shift solenoid valve SL1 circuit, the ECM determines that there is a malfunction (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- The shift solenoid valve SL1 turns ON/OFF normally when the shift lever is on D:
ECM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve SL1
OFF
OFF
OFF
OFF
ON
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1) |
Disconnect the E1 wire connector.

Measure the resistance of the wire connector.
- Standard resistance:
Tester Connection
Condition
Specified Condition
12 (SL1+) - 4 (SL1-)
20°C (68°F)
5.0 to 5.6 Ω
12 (SL1+) - Body ground
20°C (68°F)
10 kΩ or higher
4 (SL1-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
Disconnect the E16 ECM connector.

Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E16-19 (SL1+) - E16-18 (SL1-)
20°C (68°F)
5.0 to 5.6 Ω
E16-19 (SL1+) - Body ground
20°C (68°F)
10 kΩ or higher
E16-18 (SL1-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SL1 |
![]() ![]() |
Remove the shift solenoid valve SL1.
Measure the resistance of the solenoid valve.
- Standard resistance:
- 5.0 to 5.6 Ω at 20°C (68°F)
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
Check the operating noise of the solenoid valve.
- OK:
- Solenoid makes operating noise.
- HINT:
-


- Reference: Inspect using an oscilloscope.
- Check the waveform of the ECM connector.
- OK:
- Refer to illustration.
Item
Content
Tester Connection
E16-19 (SL1+) - E16-18 (SL1-)
Tool Setting
5 V/DIV., 1 msec./DIV.
Condition
Engine is idling
|
|
||||
| OK | ||
| ||