P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)
Diagnostic trouble codes · Vehicles built from Jun 2011
DESCRIPTION
Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the TCM. If an open or short circuit occurs in the shift solenoid valves, the TCM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P0778 |
TCM checks for an open or short in shift solenoid valve SL2 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic) Output signal duty equal to 100%
|
|
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The TCM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. Also, the TCM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the TCM stops sending current to the circuit.While driving and shifting between 4th and 5th gears, if the TCM detects an open or short in the shift solenoid valve SL2 circuit, the TCM determines that there is a malfunction (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- The shift solenoid valve SL2 turns ON/OFF normally when the shift lever is on D:
TCM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve SL2
ON
ON
ON
ON
OFF
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2) |
Disconnect the E1 transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
11 (SL2+) - 3 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
11 (SL2+) - Body ground
20°C (68°F)
10 kΩ or higher
3 (SL2-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
Disconnect the T19 TCM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
T19-7 (SL2+) - T19-6 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
T19-7 (SL2+) - Body ground
20°C (68°F)
10 kΩ or higher
T19-6 (SL2-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SL2 |
Remove the shift solenoid valve SL2.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 1
- Battery negative (-) → Terminal 2
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 1
|
|
||||
| OK | ||
| ||