2014 Hilux · Service Manual HEATER & AIR CONDITIONING SYSTEM

INSPECTION

Inspection · Vehicles built from Jun 2011


INSPECT THERMISTOR ASSEMBLY

E106870E26
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
    1. When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (refer to the graph).
    If the result is not as specified, replace the thermistor assembly (ambient temperature sensor).

    Text in Illustration 
    *a
    Component without harness connected
    (Thermistor Assembly (Ambient Temperature Sensor))
    *b
    Sensor Part
    *c
    Resistance kΩ
    *d
    Temperature °C (°F)

← REMOVAL (from Jun 2011)INSTALLATION (from Jun 2011) →