INSPECTION
Inspection · Vehicles built from Jun 2011
| INSPECT SPEED SENSOR (NC0) |
![]() ![]() |
Measure the resistance of the sensor.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
560 to 680 Ω
| INSPECT SPEED SENSOR (SP2) |
![]() ![]() |
Measure the resistance of the sensor.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
560 to 680 Ω