2014 Hilux · Service Manual ENGINE

TC and CG Terminal Circuit

Circuit diagnosis · Vehicles built from Jun 2011

DESCRIPTION

Terminals TC and CG are located in the DLC3.
The DLC3 is located under the instrument panel under cover. When terminals TC and CG are connected, DTC in normal mode or test mode can be read from the Malfunction Indicator Lamp (MIL) in the combination meter.
Also, terminal SIL is located in the DLC3. This terminal is used by the M-OBD communication with intelligent tester.

WIRING DIAGRAM

A261037E01

INSPECTION PROCEDURE


1. CHECK DLC3 (CHECK VOLTAGE)

  1. A058596E03
    Measure the voltage of the DLC3 connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    D1-16 (BAT) - D1-4 (CG)
    9 to 14 V



NG
Go to step 3
OK


2. CHECK WIRE HARNESS (ECM - DLC3)

  1. A110543E03
    Disconnect the E20 ECM connector.

  1. Measure the resistance of the wire harness side connectors

    Standard resistance:
    Tester Connection
    Specified Condition
    D1-7 (SIL) - E20-15 (SIL)
    Below 1 Ω
    D1-13 (TC) - E20-4 (TC)
    Below 1 Ω
    E20-15 (SIL) - Body ground
    10 kΩ or higher
    E20-4 (TC) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM

3. CHECK DLC3

  1. A058596E04
    Measure the resistance of the DLC3 connector and body ground.

    Standard resistance:
    Tester Connection
    Specified Condition
    D1-4 (CG) - Body ground
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


4. INSPECT FUSE (OBD FUSE)

  1. A121708E01
    Remove the OBD fuse from the instrument panel junction block.

  1. Measure the resistance of the OBD fuse.

    Standard resistance:
    Tester Connection
    Specified Condition
    OBD fuse
    Below 1 Ω (continuity)



NG
CHECK FOR SHORT IN ALL HARNESSES AND COMPONENTS CONNECTED TO FUSE, AND REPLACE FUSE
OK

CHECK AND REPLACE HARNESS AND CONNECTOR (DLC3 - BATTERY)