ON-VEHICLE INSPECTION
Inspection · Vehicles built from Jun 2011
| INSPECT DECELERATION SENSOR |
![]() ![]() |
Connect 3 dry cell batteries of 1.5 V in series (approximately 4.5 V total).
Connect the batteries' positive (+) lead to terminal 3 (VGS) and the negative (-) lead to terminal 2 (GGND).
- NOTICE:
- Do not apply 6 V or higher to terminals 3 (VGS) and 2 (GGND).
Connect the voltmeter's positive (+) lead to the negative (-) lead of the batteries, and the negative (-) lead to terminal 1 (GL1).
Check the output voltage of terminal 1 (GL1) when the sensor is tilted forward and rearward.
- Standard Voltage:
Tester Connection
Sensor Position
Specified Condition
1 (GL1) - Battery's negative (-) lead
Horizontal
Approx. 2.25 V
1 (GL1) - Battery's negative (-) lead
Tilted forward
Approx. 0.45 to 2.25 V
1 (GL1) - Battery's negative (-) lead
Tilted rearward
Approx. 2.25 to 4.05 V
- HINT:
- If voltage drops, the sensor should be replaced with a new one.
- When replacing the sensor, it should not be placed upside down.
- If voltage drops, the sensor should be replaced with a new one.