TC and CG Terminal Circuit
Circuit diagnosis · Vehicles built from Jun 2011
DESCRIPTION
Terminals TC and CG are located in the DLC3. When connecting these terminals, DTCs in normal mode or check mode can be determined through MIL flashing patterns in the combination meter.WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- If either of the following symptoms is present, it is determined that an open or a short in the wire harness has occurred, or there has been a malfunction in the ECM.
- The MIL displaying function does not work even though terminals TC and CG of the DLC3 are connected.
- The MIL flashes even though terminals TC and CG of the DLC3 are not connected.
- The MIL displaying function does not work even though terminals TC and CG of the DLC3 are connected.
| 1. CHECK DLC3 (TC VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the DLC3.
- Standard voltage:
Tester Connection
Specified Condition
D1-13 (TC) - D1-4 (CG)
9 to 14 V
|
|
||||
| NG | |
| 2. CHECK WIRE HARNESS (DLC3 - ECM) |
![]() ![]() |
Disconnect the E10 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
D1-13 (TC) - E10-17 (TC)
Below 1 Ω
D1-13 (TC) or E10-17 (TC) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. CHECK IF MIL BLINKS |
![]() ![]() |
Turn the ignition switch ON.
Using SST, connect terminals TC and CG of the D1 DLC3.
Check that the MIL blinks.
- OK:
- The MIL blinks.
- SST
- 09843-18040
|
|
||||
| OK | ||
| ||