TERMINALS OF ECU
System information · Vehicles built from Jun 2011
| CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (w/o PTC HEATER) |


Disconnect the A9 air conditioning amplifier connector.
Measure the voltage and resistance of the wire harness side connector.
Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
IG+ (A9-10) - GND (A9-18)
R-L - L
Power source (IG)
Ignition switch OFF
Below 1 V
IG+ (A9-10) - GND (A9-18)
R-L - L
Power source (IG)
Ignition switch ON
10 to 14 V
GND (A9-18) - Body ground
L - Body ground
Ground
Always
Below 1 Ω
ACON (A9-4) - GND (A9-18)
R-G - L
A/C switch signal
A/C switch OFF
Below 1 V
ACON (A9-4) - GND (A9-18)
R-G - L
A/C switch signal
A/C switch ON
10 to 14 V
IND- (A9-13) - GND (A9-18)
R-L - L
A/C indicator light signal
A/C switch OFF
Below 1 V
IND- (A9-13) - GND (A9-18)
R-L - L
A/C indicator light signal
A/C switch ON
10 to 14 V
- If the result is not as specified, there may be a malfunction on the wire harness side.
- If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the A9 connector.
Measure the voltage and resistance of the connector.
Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
PSW (A9-3) - GND (A9-18)
Y-B - L
Air conditioner pressure switch signal
Ignition switch START
Refrigerant pressure normal: 0.18 MPa (1.9 kgf/cm2, 26 psi) to 3.03 MPa (31.0 kgf/cm2, 440 psi)
A/C switch ON
Blower switch ON
10 to 14 V
PSW (A9-3) - GND (A9-18)
Y-B - L
Air conditioner pressure switch signal
Ignition switch START
Refrigerant pressure less than 0.18 MPa (1.9 kgf/cm2, 26 psi) or more than 3.03 MPa (31.0 kgf/cm2, 440 psi)
A/C switch ON
Blower switch ON
Below 1 V
TE (A9-7) - SG-1 (A9-8)
G - P
Evaporator temperature sensor signal
Ignition switch ON
Evaporator temperature is 0°C (32°F)
Temperature control knob: MAX COOL
2.0 to 2.4 V
TE (A9-7) - SG-1 (A9-8)
G - P
Evaporator temperature sensor signal
Ignition switch ON
Evaporator temperature is 15°C (59°F)
Temperature control knob: MAX COOL
1.4 to 1.8 V
SG-1 (A9-8) - Body ground
P - Body ground
Ground for evaporator temperature sensor
Always
Below 1 Ω
MGC (A9-1) - GND (A9-18)
L-W - L
Magnet clutch signal
Ignition switch START
Magnet clutch is not engaged
Below 1 V
MGC (A9-1) - GND (A9-18)
L-W - L
Magnet clutch signal
Ignition switch START
Magnet clutch is engaged
10 to 14 V
ACT (A9-2) - GND (A9-18)
R-L - L
Magnet on permit signal
Ignition switch START
A/C switch OFF
Blower switch ON
Below 1 V
ACT (A9-2) - GND (A9-18)
R-L - L
Magnet on permit signal
Ignition switch START
A/C switch ON
Blower switch ON
10 to 14 V
AC1 (A9-14) - GND (A9-18)
Y - L
Idle-up request signal
Ignition switch START
Magnet clutch is not engaged
10 to 14 V
AC1 (A9-14) - GND (A9-18)
Y - L
Idle-up request signal
Ignition switch START
Magnet clutch is engaged
Below 1 V
- If the result is not as specified, the air conditioning amplifier may have a malfunction.
- If the result is not as specified, the air conditioning amplifier may have a malfunction.
| CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (w/ PTC HEATER) |


Disconnect the A48 air conditioning amplifier connector.
Measure the voltage and resistance of the wire harness side connector.
Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
IG (A48-20) - GND (A48-29)
R-L - Y
Power source (IG)
Ignition switch OFF
Below 1V
IG (A48-20) - GND (A48-29)
R-L - Y
Power source (IG)
Ignition switch ON
10 to 14 V
GND (A48-29) - Body ground
Y - Body ground
Ground
Always
Below 1 Ω
ACON (A48-8) - GND (A48-29)
R-G - Y
A/C switch signal
Ignition switch ON
Blower switch OFF
A/C switch OFF
Below 1 V
ACON (A48-8) - GND (A48-29)
R-G - Y
A/C switch signal
Ignition switch ON
Blower switch ON
A/C switch ON
10 to 14 V
IND- (A48-9) - GND (A48-29)
R-L - Y
A/C indicator light signal
Ignition switch ON
Blower switch OFF
A/C switch OFF
Below 1 V
IND- (A48-9) - GND (A48-29)
R-L - Y
A/C indicator light signal
Ignition switch ON
Blower switch ON
A/C switch ON
10 to 14 V
BLW (A48-38) - GND (A48-29)
R-L - Y
Max. HOT switch signal
Ignition switch ON
Temperature control knob: Max HOT
Below 1 Ω
BLW (A48-38) - GND (A48-29)
R-L - Y
Max. HOT switch signal
Ignition switch ON
Temperature control knob: except Max HOT
10 kΩ or higher
HEAT (A48-5) - GND (A48-29)
L-O - Y
Heater switch signal
Heater switch ON
Below 1 Ω
HEAT (A48-5) - GND (A48-29)
L-O - Y
Heater switch signal
Heater switch OFF
10 kΩ or higher
MGC (A48-19) - GND (A48-29)
B - Y
Magnet clutch relay signal
Ignition switch ON
Blower switch ON
10 to 14 V
MGC (A48-19) - GND (A48-29)
B - Y
Magnet clutch relay signal
Ignition switch ON
Blower switch OFF
Below 1 V
TAIL (A48-7) - GND (A48-29)
G - Y
Light control switch signal
Light control switch ON
10 to 14 V
TAIL (A48-7) - GND (A48-29)
G - Y
Light control switch signal
Light control switch OFF
Below 1 V
- If the result is not as specified, there may be a malfunction on the wire harness side.
- If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the A48 connector.
Measure the voltage and resistance of the connector.
Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
PSW (A48-4) - GND (A48-29)
Y-B - Y
air conditioner pressure switch signal
Ignition switch START
Refrigerant pressure normal: 0.18 MPa (1.9 kgf/cm2, 26 psi) to 3.03 MPa (31.0 kgf/cm2, 440 psi)
A/C switch ON
Blower switch ON
10 to 14 V
PSW (A48-4) - GND (A48-29)
Y-B - Y
air conditioner pressure switch signal
Ignition switch START
Refrigerant pressure less than 0.18 MPa (1.9 kgf/cm2, 26 psi) or more than 3.03 MPa (31.0 kgf/cm2, 440 psi)
A/C switch ON
Blower switch ON
Below 1 V
TE (A48-24) - SG-1 (A48-31)
G - P
Evaporator temperature sensor signal
Ignition switch ON
Evaporator temperature is 0°C (32°F)
Temperature control knob: MAX COOL
2.0 to 2.4 V
TE (A48-24) - SG-1 (A48-31)
G - P
Evaporator temperature sensor signal
Ignition switch ON
Evaporator temperature is 15°C (59°F)
Temperature control knob: MAX COOL
1.4 to 1.8 V
SG-1 (A48-31) - Body ground
P - Body ground
Ground for evaporator temperature sensor
Always
Below 1 Ω
MGC (A48-19) - GND (A48-29)
B - Y
Magnet clutch signal
Ignition switch START
Magnet clutch is not engaged
Below 1 V
MGC (A48-19) - GND (A48-29)
B - Y
Magnet clutch signal
Ignition switch START
Magnet clutch is engaged
10 to 14 V
ACT (A48-39) - GND (A48-29)
R-L - Y
Magnet on permit signal
Ignition switch START
A/C switch OFF
Blower switch OFF
Below 1 V
ACT (A48-39) - GND (A48-29)
R-L - Y
Magnet on permit signal
Ignition switch START
A/C switch ON
Blower switch ON
10 to 14 V
AC1 (A48-35) - GND (A48-29)
Y - Y
Idle-up request signal
Ignition switch START
Magnet clutch is not engaged
10 to 14 V
AC1 (A48-35) - GND (A48-29)
Y - Y
Idle-up request signal
Ignition switch START
Magnet clutch is engaged
Below 1.0 V
BLW (A48-38) - GND (A48-29)
R-L - Y
Max. HOT switch signal
Ignition switch ON
Blower switch ON
temperature control knob: Max HOT
Heater switch ON
Coolant temperature 65°C (149°F)
10 to 14 V
BLW (A48-38) - GND (A48-29)
R-L - Y
Max. HOT switch signal
Ignition switch ON
Blower switch ON
Temperature control knob: except Max HOT
Heater switch OFF
Coolant temperature 65°C (149°F)
Below 1 V
HEAT (A48-5) - GND (A48-29)
L-O - Y
Heater switch input signal
Ignition switch ON
Blower switch ON
temperature control knob: Max HOT
Heater switch ON
Coolant temperature 65°C (149°F)
Below 1 V
HEAT (A48-5) - GND (A48-29)
L-O - Y
Heater switch input signal
Ignition switch ON
Blower switch ON
Temperature control knob: except Max HOT
Heater switch OFF
Coolant temperature 65°C (149°F)
10 to 14 V
SWIN (A48-15) - GND (A48-29)
P - Y
Heater switch indicator light signal
Ignition switch ON
Blower switch ON
temperature control knob: Max HOT
Heater switch ON
Coolant temperature 65°C (149°F)
Below 1 V
SWIN (A48-15) - GND (A48-29)
P - Y
Heater switch indicator light signal
Ignition switch ON
Blower switch ON
Temperature control knob: except Max HOT
Heater switch OFF
Coolant temperature 65°C (149°F)
10 to 14 V
PTCR (A48-26) - GND (A48-29)
L-W - Y
Heater switch output signal
Ignition switch ON
Blower switch ON
temperature control knob: Max HOT
Heater switch ON
Coolant temperature 65°C (149°F)
10 to 14 V
PTCR (A48-26) - GND (A48-29)
L-W - Y
Heater switch output signal
Ignition switch ON
Blower switch ON
Temperature control knob: except Max HOT
Heater switch OFF
Coolant temperature 65°C (149°F)
Below 1 V
TW (A48-32) - GND (A48-29)
P - Y
Water temperature signal
Ignition switch ON
Pulse generation
TACO (A48-33) - GND (A48-29)
B-W - Y
Tachometer signal
Engine running
Pulse generation
(see waveform 1)
ALT (A48-37) - GND (A48-29)
G - Y
Generator
Engine running
Pulse generation
PTC1 (A48-3) - GND (A48-29)
R-W - Y
PTC heater relay signal
Ignition switch ON
Blower switch ON
temperature control knob: Max HOT
Heater switch ON
Coolant temperature 65°C (149°F)
Below 1 V
PTC1 (A48-3) - GND (A48-29)
R-W - Y
PTC heater relay signal
Ignition switch ON
Blower switch ON
Temperature control knob: except Max HOT
Heater switch OFF
Coolant temperature 65°C (149°F)
10 to 14 V
PTC2 (A48-2) - GND (A48-29)
GR - Y
PTC heater relay signal
Ignition switch ON
Blower switch ON
temperature control knob: Max HOT
Heater switch ON
Coolant temperature 65°C (149°F)
Below 1 V
PTC2 (A48-2) - GND (A48-29)
GR - Y
PTC heater relay signal
Ignition switch ON
Blower switch ON
Temperature control knob: except Max HOT
Heater switch OFF
Coolant temperature 65°C (149°F)
10 to 14 V
- If the result is not as specified, the air conditioning amplifier may have a malfunction.
- If the result is not as specified, the air conditioning amplifier may have a malfunction.
Inspect using an oscilloscope.

Waveform 1 (Reference)
Item
Content
Symbols (Terminal No.)
TACO (A48-33) - GND (A48-29)
Tool Setting
5 V/DIV., 20 msec./DIV.
Condition
Engine idling
- HINT:
- As engine speed increases, the wavelength shortens.
| CHECK ECM |


Measure the voltage of the connectors.
1TR-FE, 2TR-FE
Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
ACT (E10-25) - E01 (E12-7)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch OFF
Blower switch OFF
Below 1 V
ACT (E10-25) - E01 (E12-7)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch ON
Blower switch ON
10 to 14 V
AC1 (E10-24) - E01 (E12-7)
Y - W-B
Idle-up request signal
Ignition switch START
Magnet clutch is engaged
Below 1.0 V
AC1 (E10-24) - E01 (E12-7)
Y - W-B
Magnet on permit signal
Ignition switch START
Magnet clutch is not engaged
10 to 14 V
- If the result is not as specified, the ECM may have a malfunction.
- If the result is not as specified, the ECM may have a malfunction.
1KD-FTV, 2KD-FTV
Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
ACT (E6-19) - E01 (E8-7)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch OFF
Blower switch OFF
Below 1 V
ACT (E6-19) - E01 (E8-7)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch ON
Blower switch ON
10 to 14 V
AC1 (E6-18) - E01 (E8-7)
Y - W-B
Idle-up request signal
Ignition switch START
Magnet clutch is engaged
Below 1 V
AC1 (E6-18) - E01 (E8-7)
Y - W-B
Magnet on permit signal
Ignition switch START
Magnet clutch is not engaged
10 to 14 V
THWO (E5-2) - E01 (E8-7)*
P - W-B
Water temperature signal
Ignition switch START
Pulse generation
HSW (E6-20) - E01 (E8-7)*
L-W - W-B
Heater switch output signal for idle-up
Ignition switch START
Heater switch ON
Blower switch ON
Temperature control knob: Max HOT
Coolant temperature 65°C (149 °F)
Below 1 V
HSW (E6-20) - E01(E8-7)*
L-W - W-B
Heater switch output signal for idle-up
Ignition switch START
Heater switch OFF
Blower switch ON
Temperature control knob: except Max HOT
Coolant temperature 65°C (149 °F)
10 to 14 V
TACH (E5-4) - E01 (E8-7)*
B-W - W-B
Tachometer signal
Engine running
Pulse generation
(see waveform 1)
- If the result is not as specified, the ECM may have a malfunction.
- HINT:
- *: w/ PTC Heater
- If the result is not as specified, the ECM may have a malfunction.
1GR-FE
Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
ACT (E13-25) - E01 (E15-7)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch OFF
Blower switch OFF
Below 1 V
ACT (E13-19) - E01 (E15-7)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch ON
Blower switch ON
10 to 14 V
AC1 (E13-24) - E01 (E15-7)
Y - W-B
Idle-up request signal
Ignition switch START
Magnet clutch is engaged
Below 1 V
AC1 (E13-24) - E01 (E15-7)
Y - W-B
Magnet on permit signal
Ignition switch START
Magnet clutch is not engaged
10 to 14 V
- If the result is not as specified, the ECM may have a malfunction.
- If the result is not as specified, the ECM may have a malfunction.
5L-E


Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specified Condition
ACT (E21-8) - E01 (E23-13)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch OFF
Blower switch OFF
Below 1 V
ACT (E21-8) - E01 (E23-13)
R-L - W-B
Magnet on permit signal
Ignition switch START
A/C switch ON
Blower switch ON
10 to 14 V
AC1 (E21-2) - E01 (E23-13)
Y - W-B
Idle-up request signal
Ignition switch START
Magnet clutch is engaged
Below 1 V
AC1 (E21-2) - E01 (E23-13)
Y - W-B
Magnet on permit signal
Ignition switch START
Magnet clutch is not engaged
10 to 14 V
- If the result is not as specified, the ECM may have a malfunction.
- If the result is not as specified, the ECM may have a malfunction.
Inspect using an oscilloscope (w/ PTC heater only).

Waveform 1 (Reference)
Item
Content
Symbols (Terminal No.)
TACH (E5-4) - E01 (E8-7)
Tool Setting
5 V/DIV., 20 msec./DIV.
Condition
Engine idling
- HINT:
- As engine speed increases, the wavelength shortens.