P0627 Fuel Pump Control Circuit / Open
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
- HINT:
- For more information on the supply pump (suction control valve) and the common rail system, refer to the system description (Click here).
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0627 |
Open or short in suction control valve circuit for more than 0.5 seconds (1 trip detection logic) |
|
- HINT:
- When DTC P0627 is set, check the internal fuel pressure of the common rail by entering the following menus on the intelligent tester: Powertrain / Engine / Data List / Fuel Press.
- Reference (for Waste Gate Type Turbocharger):
Engine Speed
Fuel Pressure
Idling
Approximately 25000 to 35000 kPa
3000 rpm (No engine load)
Approximately 28000 to 48000 kPa
- Reference (for Variable Nozzle Vane Turbocharger):
Engine Speed
Fuel Pressure
Idling
Approximately 25000 to 35000 kPa
3000 rpm (No engine load)
Approximately 50000 to 70000 kPa
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
- NOTICE:
- If the ECM is replaced, the new ECM needs initialization (Click here).
- If the supply pump is replaced, the ECM needs initialization (Click here).
- If the ECM is replaced, the new ECM needs initialization (Click here).
| 1. INSPECT SUPPLY PUMP ASSEMBLY (SUCTION CONTROL VALVE) |
![]() ![]() |
Disconnect the S8 suction control valve connector.
Measure the resistance of the suction control valve.
- Standard resistance:
- 1.9 to 2.3 Ω at 20°C (68°F)
|
|
||||
| OK | |
| 2. CHECK WIRE HARNESS (SUCTION CONTROL VALVE - ECM) |
![]() ![]() |
Disconnect the S8 valve connector.
Disconnect the E8 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
S8-1 (PCV+) - E8-2 (PCV+)
Below 1 Ω
S8-2 (PCV-) - E8-1 (PCV-)
Below 1 Ω
S8-1 (PCV+) - E8-2 (PCV+) - Body ground
10 kΩ or higher
S8-2 (PCV-) - E8-1 (PCV-) - Body ground
10 kΩ or higher
|
|
||||
| OK | |
| 3. CHECK ECM (PCV SIGNAL) |
![]() ![]() |
While cranking or idling the engine, check the waveform of the ECM connector using an oscilloscope.
- OK:
Tester Connection
Specified Condition
E8-2 (PCV+) - E8-1 (PCV-)
Correct waveform is shown
Tool Setting
Condition
10 V/DIV., 5 msec./DIV.
Idling or cranking with warm engine
- HINT:
- The waveform varies depending on the suction control valve operation.
|
|
||||
| OK | ||
| ||