P0180 Fuel Temperature Sensor Circuit Malfunction
Diagnostic trouble codes · Vehicles built Aug 2012 – Jul 2013
Also covers:
- P0182 Fuel Temperature Sensor "A" Circuit Low Input
- P0183 Fuel Temperature Sensor "A" Circuit High Input
Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The fuel temperature sensor monitors the fuel temperature. The fuel temperature sensor has a thermistor that varies its resistance depending on the fuel temperature. When the fuel temperature is low, the resistance in the thermistor increases. When the temperature is high, the resistance decreases. The variations in resistance are communicated to the ECM as changes in voltage (see Fig. 1).

The fuel temperature sensor is connected to the ECM. The 5 V power source voltage in the ECM is applied to the fuel temperature sensor from terminal THF via resistor R.
The resistor R and fuel temperature sensor are connected in series. When the resistance value of the fuel temperature sensor changes in accordance with changes in the fuel temperature, the voltage at terminal THF also changes. Based on this signal, the ECM corrects the pressure control compensation of the supply pump and errors.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0180 |
Open or short in fuel temperature sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0182 |
Short in fuel temperature sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0183 |
Open in fuel temperature sensor circuit for 0.5 seconds (1 trip detection logic) |
|
- HINT:
- When DTC P0180/39, P0182/39 and/or P0183/39 is detected, check the fuel temperature by entering the following menus on the intelligent tester: Powertrain / Engine / Data List / Fuel Temperature.
Temperature Displayed
Malfunction
-40°C (-40°F)
Open circuit
140°C (284°F) or more
Short circuit
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- If the ECM is replaced, the new ECM needs registration (Click here) and initialization (Click here).
- HINT:
- If DTCs related to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, and other data from the time the malfunction occurred.
- If DTCs related to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
| 1. READ VALUE USING INTELLIGENT TESTER (FUEL TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Enter the following menus: Powertrain / Engine / Data List / Fuel Temp.
Read the value displayed on the intelligent tester.
- Temperature:
- Same value as the actual fuel temperature.
- Result:
Temperature Displayed
Proceed to
-40°C (-40°F)
A
140°C (284°F) or more
B
OK (Same as actual fuel temperature)
C
- HINT:
- If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
- If there is a short circuit, the intelligent tester indicates 140°C (284°F) or more.
- If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
|
|
||||
|
|
||||
| A | |
| 2. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN WIRE HARNESS) |
Disconnect the F11 fuel temperature sensor connector.

Connect terminals 1 and 2 of the fuel temperature sensor wire harness side connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Enter the following menus: Powertrain / Engine / Data List / Fuel Temp.
Read the value.
- Standard:
- 140°C (284°F) or more
|
|
||||
| NG | |
| 3. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN ECM) |
Disconnect the E8 ECM connector.

Disconnect the F11 fuel temperature sensor connector.
Connect terminals THF and E2 of the E8 ECM connector.
- HINT:
- Before checking, do a visual and contact pressure check on the ECM connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Read the value displayed.
- Standard:
- 140°C (284°F) or more
|
|
||||
| NG | ||
| ||
| 4. READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS) |
Disconnect the F11 fuel temperature sensor connector.

Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the intelligent tester ON.
Enter the following menus: Powertrain / Engine / Data List / Fuel Temp.
Read the value.
- Standard:
- -40°C (-40°F)
|
|
||||
| NG | |
| 5. REPAIR OR REPLACE INTELLIGENT TESTER (CHECK FOR SHORT IN ECM) |
Disconnect the F11 fuel temperature sensor connector.

Disconnect the E17 ECM connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Enter the following menus: Powertrain / Engine / Data List / Fuel Temp.
Read the value.
- Standard:
- -40°C (-40°F)
|
|
||||
| NG | ||
| ||