2014 Hilux · Service Manual ENGINE

P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2)

Diagnostic trouble codes · Vehicles built from Jun 2011

Also covers:

CAUTION / NOTICE / HINT

HINT:
  1. Sensor 1 refers to the sensor mounted before the Three-Way Catalytic Converter (TWC) and is located near the engine assembly.
  2. Sensor 2 refers to the sensor mounted after the TWC and is located far from the engine assembly.


DESCRIPTION

In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC is used. For the most efficient use of the TWC, the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel level. To help the ECM to deliver accurate air-fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-TWC air-fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-TWC air-fuel ratio is rich (high voltage, i.e. more than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air-fuel ratio after the TWC is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air-fuel ratio control.
A088111E02

HINT:
The ECM provides a pulse width modulated control circuit to adjust current through the heater. The heated oxygen sensor heater circuit uses a relay on the +B side of the circuit.

A078602E44
DTC No.
DTC Detection Condition
Trouble Area
P0037
Heated current is 0.3 A or less when heater operates
(1 trip detection logic)
  1. Open in heater circuit of heated oxygen sensor
  2. Heated oxygen sensor heater
  3. MAIN relay
  4. ECM
P0038
Heated current exceeds 2 A when heater operates
(1 trip detection logic)
  1. Short in heater circuit of heated oxygen sensor
  2. Heated oxygen sensor heater
  3. MAIN relay
  4. ECM

MONITOR DESCRIPTION

The sensing portion of the heated oxygen sensor has a zirconia element which is used to detect oxygen concentration in the exhaust. If the zirconia element is at the proper temperature and the difference of the oxygen concentration between the inside and outside surface of the sensor is large, the zirconia element will generate voltage signals. In order to increase the oxygen concentration detecting capacity in the zirconia element, the ECM supplements the heat from the exhaust with the heat from the heating element inside the sensor. When current in the sensor is out of the standard operating range, the ECM interprets this as a fault in the heated oxygen sensor and sets a DTC.
Example:
The ECM will set a high-current DTC if the current in the sensor is more than 2 A when the heater is on. Similarly, the ECM will set a low-current DTC if the current is less than 0.3 A when the heater is on.

WIRING DIAGRAM

Refer to DTC P0136 (Click here).

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)
A062378E23
  1. Disconnect the H7 sensor connector.

  1. Measure the resistance of the heated oxygen sensor.

    Standard:
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher



NG
REPLACE HEATED OXYGEN SENSOR
OK


2. INSPECT INTEGRATION NO.1 RELAY (MAIN RELAY)
G039047E12
  1. Remove the integration relay from the engine room junction block.

  1. Measure the voltage of the MAIN relay.

    Standard:
    Tester Connection
    Condition
    Specified Condition
    1J-5 - Body ground
    Ignition switch ON
    10 to 14 V



NG
REPLACE INTEGRATION NO.1 RELAY
OK


3. INSPECT ECM (HT1B VOLTAGE)
A066060E57
  1. Turn the ignition switch ON.

  1. Measure the voltage of the E12 ECM connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    E12-2 (HT1B) - E12-3 (E1)
    9 to 14 V



OK
REPLACE ECM
NG


4. CHECK WIRE HARNESS (HEATED OXYGEN SENSOR - ECM, INTEGRATION RELAY (MAIN RELAY))
G038630E08
  1. Disconnect the H7 sensor connector.

  1. Disconnect the E12 ECM connector.

  1. Disconnect the 1J connector from the engine room junction block.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    H7-1 (HT1B) - E12-2 (HT1B)
    Below 1 Ω
    H7-2 (+B) - 1J-5
    Below 1 Ω
    H7-1 (HT1B) or E12-2 (HT1B) - Body ground
    10 kΩ or higher
    H7-2 (+B) or 1J-5 - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM


← P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) (+ P0032) (from Jun 2011)P0100/31 Mass Air Flow Circuit Malfunction (+ P0102/31, P0103/31) (from Jun 2011) →