P2716/77 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built from Jun 2011
DESCRIPTION
The throttle pressure that is applied to the primary regulator valve (which modulates the line pressure) causes the solenoid valve SLT, under electronic control, to precisely modulate and generate the line pressure according to the extent that the accelerator pedal is depressed or the output of engine power.This controls the line pressure and provides smooth shifting characteristics.
Upon receiving a signal of the throttle valve opening angle, the ECM controls the line pressure by sending a predetermined duty ratio* to the solenoid valve, modulating the line pressure and generating throttle pressure.
- HINT:
-


- *: The duty ratio is the ratio of the current on time (A) to the total of the current on and off time (A + B).
- Duty Ratio (%) = A / (A + B) x 100
| DTC Code |
DTC Detection Condition |
Trouble Area |
| P2716/77 |
ECM detects shift solenoid valve SLT circuit malfunction for 1 sec. or more (1 trip detection logic) |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
Disconnect the E1 wire connector.

Measure the resistance of the transmission wire.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
2 (SLT+) - 6 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
2 (SLT+) - Body ground
20°C (68°F)
10 kΩ or higher
6 (SLT-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK WIRE HARNESS (SHIFT SOLENOID VALVE SLT - ECM) |
Disconnect the E11 ECM connector.

Measure the resistance of the wire harness side connector.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E11-12 (SLT+) - E11-13 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
E11-12 (SLT+) - Body ground
20°C (68°F)
10 kΩ or higher
E11-13 (SLT-) - Body ground
20°C (68°F)
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLT |
![]() ![]() |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

- OK:
- Valve moves and makes an operating noise.
- HINT:
-


- Reference: Inspect using an oscilloscope.
- Check the waveform of the ECM connector.
- OK:
- Refer to illustration
Item
Content
Tester Connection
E11-12 (SLT+) - E11-13 (SLT-)
Tool Setting
5 V/DIV., 1 msec./DIV.
Condition
Engine is idling
|
|
||||
| OK | ||
| ||