2014 Hilux · Service Manual TRANSMISSION

P0973/62 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)

Diagnostic trouble codes · Vehicles built from Jun 2011

Also covers:

DESCRIPTION

Shifting from 1st to 4th is performed in combination with the ON and OFF operation of the shift solenoid valves S1 and S2 controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely (fail-safe function).
Fail-safe function:
If either of the shift solenoid valve circuits develops an open or short, the ECM turns the other shift solenoid ON and OFF to shift to the gear positions shown in the table below. The ECM also turns the shift solenoid valve SL OFF at the same time. If both solenoids are malfunctioning, electronic hydraulic control does not operate and must be performed manually. Manual shifting as shown in the following table must be performed.
In case of a short circuit, the ECM stops sending current to the circuit.
Position
Normal
Shift Solenoid S1 Malfunctioning
Shift Solenoid S2 Malfunctioning
Both Solenoids Malfunctioning
Solenoid valve
Gear
Solenoid valve
Gear
Solenoid valve
Gear
Gear when shift selector is manually operated
S1
S2
S1
S2
S1
S2
D
ON
OFF
1st
X
ON
3rd
ON
X
1st
4th
ON
ON
2nd
X
ON
3rd
OFF
X
4th
4th
OFF
ON
3rd
X
ON
3rd
OFF
X
4th
4th
OFF
OFF
4th
X
OFF
4th
OFF
X
4th
4th
2
ON
OFF
1st
X
ON
3rd
ON
X
1st
3rd
ON
ON
2nd
X
ON
3rd
OFF
X
3rd
3rd
OFF
ON
3rd
X
ON
3rd
OFF
X
3rd
3rd
L
ON
OFF
1st
X
OFF
1st
ON
X
1st
1st
ON
ON
2nd
X
ON
2nd
ON
X
1st
1st

HINT:
X: Malfunction

DTC No.
DTC Detection Condition
Trouble Area
P0973/62
ECM detects short in solenoid valve S1 circuit 4 times when solenoid valve S1 is operated (1 trip detection logic)
  1. Short in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM
P0974/62
ECM detects open in solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated (1 trip detection logic)
  1. Open in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM
P0976/63
ECM detects short in solenoid valve S2 circuit 4 times when solenoid valve S2 is operated (1 trip detection logic)
  1. Short in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM
P0977/63
ECM detects open in solenoid valve S2 circuit 4 times when solenoid valve S2 is not operated (1 trip detection logic)
  1. Open in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM

MONITOR DESCRIPTION

The ECM controls gear shift by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores a DTC.
The ECM performs the fail-safe function and turns the normally functioning shift solenoid valve ON/OFF.
In case of an open or short circuit, the ECM stops sending current to the circuit.

WIRING DIAGRAM

C169746E04

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1/S2)

  1. C170576E01
    Disconnect the E1 wire connector.

  1. Measure the resistance of the transmission wire.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    4 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω
    8 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω



NG
Go to step 3
OK


2. CHECK WIRE HARNESS (SHIFT SOLENOID VALVE S1/S2 - ECM)

  1. C117621E31
    Disconnect the E11 ECM connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E11-9 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω
    E11-8 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM

3. INSPECT SHIFT SOLENOID VALVE S1/S2
C169051E01
  1. Remove the shift solenoid valve S1/S2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body
    20°C (68°F)
    11 to 15 Ω
    Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE S1/S2
OK

REPLACE TRANSMISSION WIRE


← P0818 Driveline Disconnect Switch Input Circuit (from Aug 2014)P2716/77 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) (from Jun 2011) →