ON-VEHICLE INSPECTION
Inspection · Vehicles built from Jun 2011
| CHECK FOR LEAKS |
Visually check that the hoses, connections and gaskets have no cracks, leaks or damage.
- NOTICE:
- Detachment or other problems with the engine oil dipstick, filler cap, PCV hose and other components may cause the engine to run improperly.
- Detachment or other problems with the engine oil dipstick, filler cap, PCV hose and other components may cause the engine to run improperly.
- Air suction caused by disconnections, looseness or cracks in the parts of the air induction system between the throttle body and cylinder head will cause engine failure or engine malfunctions.
- Air suction caused by disconnections, looseness or cracks in the parts of the air induction system between the throttle body and cylinder head will cause engine failure or engine malfunctions.
| CHECK VACUUM SWITCHING VALVE (for EVAP) |
Check that the vacuum hose is connected correctly.

Disconnect the vacuum hose from the canister, and connect a vacuum gauge.
Using the flowchart below, perform a VSV operation inspection when the engine coolant temperature is 55°C (131°F) or less (while the engine is cold (VSV is closed)).
- HINT:
- The ECM turns the VSV off so that the route between the canister and intake manifold is closed, and fuel vapor in the canister is not purged to the intake manifold.
VSV operation flowchart.
1. When the engine is idling or running and at 2,500 rpm, the vacuum gauge indicates 1 kPa (25 mmHg, 0.3 in.Hg) or less.- Result:
Result
Procedure
Yes
VSV operation normal
No
Go to next step
- Result:
Result
Procedure
OK
Check wire harness and ECM
NG
Replace VSV
Using the flowchart below, perform a VSV operation inspection when the engine coolant temperature is 80°C (146°F) or more (while the engine is hot (VSV is opened)).
- HINT:
- The ECM turns the VSV on so that a vacuum is created in the intake manifold and the canister's fuel vapors are purged to the intake manifold.
VSV operation flowchart.
1. When the engine is idling, the vacuum gauge indicates 40 kPa (300 mmHg, 11.8 in.Hg) or more.- Result:
Result
Procedure
Yes
VSV operation normal
No
Go to next step
- Result:
Result
Procedure
OK
Check wire harness and ECM
NG
Replace VSV