INSPECTION
Inspection · Vehicles built from Jun 2011
| INSPECT HEATED OXYGEN SENSOR |
 |
- Measure the resistance between terminals 1 (HT) and 2 (+B) of the sensor.
- Standard resistance:
- 5 to 10 Ω at 20°C (68°F)
If the result is not as specified, replace the heated oxygen sensor.