2014 Hilux · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from Jun 2011

for 2.0 kW Type
Starter
No-load characteristics current
100 A or less at 11.5 V
Starter armature assembly
Maximum circle runout
0.05 mm (0.0020 in.)
Standard commutator diameter
35.0 mm (1.378 in.)
Minimum commutator diameter
34.0 mm (1.339 in.)
Standard undercut depth
0.7 mm (0.028 in.)
Minimum undercut depth
0.2 mm (0.008 in.)
Segments
Below 1 Ω
Segment - Coil core
10 kΩ or higher
Brush length
Standard length
15.0 mm (0.591 in.)
Minimum length
9.0 mm (0.354 in.)
Brush spring
Standard spring installed load
21.5 to 27.5N
(2.2 to 2.8 kgf*cm, 4.8 to 6.2 in.*lbf)
Minimum spring installed load
12.7 N (1.3 kgf*cm, 2.9 in.*lbf)
Starter yoke
Lead wire - Field coil brush lead
Below 1 Ω
Shunt coil terminals
1.5 to 1.9 Ω at 20°C(68°F)
Brush holder
Positive brush - Negative brush
10 kΩ or higher
Magnet starter switch
Terminal 50 - Terminal C
Below 1 Ω
Terminal 50 - Body
Below 2 Ω
for 2.2 kW Type
Starter
No-load characteristics current
123 A or less at 11.5 V
Starter armature
Maximum circle runout
0.04 mm (0.0016 in.)
Standard circle runout
0.02 mm (0.0008 in.)
Standard commutator diameter
32.2 mm (1.2783 in.)
Minimum commutator diameter
31.1 mm (1.2347 in.)
Standard undercut depth
0.9 mm (0.03543 in.)
Minimum undercut depth
0.4 mm (0.0157 in.)
Segments
Below 1.7 Ω
Segment - Coil core
10 kΩ or higher
Brush
Standard length
14.0 mm (0.5558 in.)
Minimum length
9.0 mm (0.354 in. )
Tester connection
A-B
10 kΩ or higher
Tester connection
A-C
10 kΩ or higher
Tester connection
A-D
Below 1 Ω
Tester connection
B-C
Below 1 Ω
Tester connection
B-D
10 kΩ or higher
Tester connection
C-D
10 kΩ or higher
Magnet starter switch
Terminal 50 - Terminal C
Below 1 Ω
Terminal 50 - Body
Below 2 Ω
for 2.7 kW Type
Starter
No-load characteristics current
180 A or less at 11 V
Starter armature assembly
Maximum circle runout
0.05 mm (0.0020 in.)
Standard commutator diameter
36.0 mm (1.417 in.)
Minimum commutator diameter
35.0 mm (1.378 in.)
Standard undercut depth
0.7 mm (0.028 in.)
Minimum undercut depth
0.2 mm (0.008 in.)
Segments
Below 1 Ω
Segment - Coil core
10 kΩ or higher
Brush length
Standard length
20.5 mm (0.814 in.)
Minimum length
11.0 mm (0.433 in.)
Brush spring
Standard spring installed load
26 to 45N
(3 to 5 kgf*cm, 5.8 to 10.1 in.*lbf)
Minimum spring installed load
12 N
(1 kgf*cm, 2.8 in.*lbf)
Starter yoke
Lead wire - Field coil brush lead
Below 1 Ω
Lead wire - Starter yoke body
10 kΩ or higher
Brush holder
Positive brush - Negative brush
10 kΩ or higher
Magnet starter switch
Terminal 50 - Terminal C
Below 1 Ω
Terminal 50 - Body
Below 2 Ω
Glow plug
Resistance
Approx. 0.95 Ω
Glow plug (for DPF)
Approx. 1.0 Ω
ECT sensor
Resistance
Approx. 20°C(68°F)
2.32 to 2.59 kΩ
Approx. 80°C(176°F)
0.310 to 0.326 kΩ
Starter relay
Specified resistance
3-5
10 kΩ or higher
Below 1 Ω
(when battery voltage is applied to terminal 1 and 2)
Glow relay
Specified resistance
3-5
10 kΩ or higher
Below 1 Ω
(when battery voltage is applied to terminal 1 and 2)
← TORQUE SPECIFICATIONS (from Jun 2011)TORQUE SPECIFICATIONS (from Jun 2011) →