2014 Hilux · Service Manual RESTRAINTS

B1825/56 Short in Front Passenger Side - Side Squib Circuit

Diagnostic trouble codes · Vehicles built from Aug 2013

Also covers:

Versions by build date: Jun 2011 – Jul 2013 from Aug 2013

DESCRIPTION

The front passenger side - side squib circuit consists of the center airbag sensor and the front passenger side - side airbag.
The circuit instructs the SRS to deploy when the deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the front passenger side - side squib circuit.
DTC Code
Detection Condition
Trouble Area
B1825/56
When all conditions below are met:
  1. The center airbag sensor receives a line short circuit signal 5 times in the front passenger side - side squib circuit during primary check.
  2. Front passenger side - side squib malfunction
  3. Center airbag sensor malfunction
  1. Floor wire
  2. Front seat side airbag assembly (front passenger side)
  3. Center airbag sensor assembly
B1826/56
When all conditions below are met:
  1. The center airbag sensor receives an open circuit signal in the front passenger side - side squib circuit for 2 seconds.
  2. Front passenger side - side squib malfunction
  3. Center airbag sensor malfunction
  1. Floor wire
  2. Front seat side airbag assembly (front passenger side)
  3. Center airbag sensor assembly
B1827/56
When all conditions below are met:
  1. The center airbag sensor receives a short circuit to ground signal in the front passenger side - side squib circuit for 0.5 seconds.
  2. Front passenger side - side squib malfunction
  3. Center airbag sensor malfunction
  1. Floor wire
  2. Front seat side airbag assembly (front passenger side)
  3. Center airbag sensor assembly
B1828/56
When all conditions below are met:
  1. The center airbag sensor receives a short circuit to B+ signal in the front passenger side - side squib circuit for 0.5 seconds.
  2. Front passenger side - side squib malfunction
  3. Center airbag sensor malfunction
  1. Floor wire
  2. Front seat side airbag assembly (front passenger side)
  3. Center airbag sensor assembly

WIRING DIAGRAM

C194497E18
C194497E17

INSPECTION PROCEDURE


1. CHECK VEHICLE CONDITION
  1. Check vehicle condition.

    Result 
    Result
    Proceed to
    for RHD
    A
    for LHD
    B



B
Go to step 5
A


2. CHECK FRONT SEAT SIDE AIRBAG LH (SIDE SQUIB LH)
C198488E02
  1. Turn the ignition switch OFF.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect the connector from the front seat side airbag LH.

  1. Connect the red wire side of SST (resistance: 2.1 Ω) to connector C.

    CAUTION:
    Never connect the tester to the front seat side airbag LH (side squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert SST into the terminals of the connector when connecting SST.
    2. Insert SST straight into the terminals of the connector.

SST
09843-18061  
  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch OFF.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1825, B1826, B1827 or B1828 is not output

    HINT:
    Codes other than DTC B1825, B1826, B1827, B1828 may be output at this time, but they are not related to this check.



NG
Go to step 3
OK

REPLACE FRONT SEATBACK ASSEMBLY LH

3. CHECK FLOOR WIRE (SIDE SQUIB LH CIRCUIT)
C198489E02
  1. Turn the ignition switch OFF.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect SST from connector C.

  1. Disconnect the connectors from the center airbag sensor.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    S39-1 (SFL+) - Body ground
    Ignition switch ON
    Below 1 V
    S39-2 (SFL-) - Body ground

  1. Turn the ignition switch OFF.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    S39-1 (SFL+) - S39-2 (SFL-)
    Always
    Below 1 Ω

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    S39-1 (SFL+) - S39-2 (SFL-)
    Always
    1 MΩ or higher
    S39-1 (SFL+) - Body ground
    S39-2 (SFL-) - Body ground



NG
REPLACE FLOOR WIRE
OK


4. CHECK CENTER AIRBAG SENSOR ASSEMBLY
C198490E01
  1. Connect the connectors to the front seat side airbag LH and the center airbag sensor.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch OFF.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1825, B1826, B1827 or B1828 is not output

    HINT:
    Codes other than DTC B1825, B1826, B1827, B1828 may be output at this time, but they are not related to this check.



NG
REPLACE CENTER AIRBAG SENSOR ASSEMBLY
OK

USE SIMULATION METHOD TO CHECK

5. CHECK FRONT SEAT SIDE AIRBAG ASSEMBLY RH
C198488E04
  1. Turn the ignition switch OFF.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect the connector from the front seat side airbag RH.

  1. Connect the red wire side of SST (resistance: 2.1 Ω) to connector C.

    CAUTION:
    Never connect the tester to the front seat side airbag RH (side squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert SST into the terminals of the connector when connecting SST.
    2. Insert SST straight into the terminals of the connector.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch OFF.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1825, B1826, B1827 or B1828 is not output

    HINT:
    Codes other than DTC B1825, B1826, B1827, B1828 may be output at this time, but they are not related to this check.



NG
Go to step 6
OK

REPLACE FRONT SEATBACK ASSEMBLY RH

6. CHECK FLOOR WIRE (SIDE SQUIB RH CIRCUIT)
C198489E03
  1. Turn the ignition switch OFF.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect SST from connector C.

  1. Disconnect the connectors from the center airbag sensor.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    S38-1 (SFR+) - Body ground
    Ignition switch ON
    Below 1 V
    S38-2 (SFR-) - Body ground

  1. Turn the ignition switch OFF.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    S38-1 (SFR+) - S38-2 (SFR-)
    Always
    Below 1 Ω

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    S38-1 (SFR+) - S38-2 (SFR-)
    Always
    1 MΩ or higher
    S38-1 (SFR+) - Body ground
    S38-2 (SFR-) - Body ground



NG
REPLACE FLOOR WIRE (SIDE SQUIB LH CIRCUIT)
OK


7. CHECK CENTER AIRBAG SENSOR ASSEMBLY
C198490E02
  1. Connect the connectors to the front seat side airbag RH and the center airbag sensor.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch OFF.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1825, B1826, B1827 or B1828 is not output

    HINT:
    Codes other than DTC B1825, B1826, B1827, B1828 may be output at this time, but they are not related to this check.



NG
REPLACE CENTER AIRBAG SENSOR ASSEMBLY
OK

USE SIMULATION METHOD TO CHECK


← B1825/56 Short in Front Passenger Side - Side Squib Circuit (+ B1826/56, B1827/56, B1828/56) (Jun 2011 – Jul 2013)B1830/57 Short in Driver Side Curtain Shield Squib Circuit (+ B1831/57, B1832/57, B1833/57) (Jun 2011 – Jul 2013) →