B1830/57 Short in Driver Side Curtain Shield Squib Circuit
Diagnostic trouble codes · Vehicles built from Aug 2013
Also covers:
- B1831/57 Open in Driver Side Curtain Shield Squib Circuit
- B1832/57 Short to GND in Driver Side Curtain Shield Squib Circuit
- B1833/57 Short to B+ in Driver Side Curtain Shield Squib Circuit
Versions by build date: Jun 2011 – Jul 2013 from Aug 2013
DESCRIPTION
The driver side curtain shield squib circuit consists of the center airbag sensor and the driver side curtain shield airbag.The circuit instructs the SRS to deploy when the deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the driver side curtain shield squib circuit.
| DTC Code |
Detection Condition |
Trouble Area |
| B1830/57 |
When all conditions below are met:
|
|
| B1831/57 |
When all conditions below are met:
|
|
| B1832/57 |
When all conditions below are met:
|
|
| B1833/57 |
When all conditions below are met:
|
|
WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. CHECK VEHICLE CONDITION |
Check vehicle condition.
Result Result
Proceed to
for LHD
A
for RHD
B
|
|
||||
| A | |
| 2. CHECK CURTAIN SHIELD AIRBAG LH (CURTAIN SHIELD SQUIB) |
![]() ![]() |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the curtain shield airbag LH.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
- CAUTION:
- Never connect the tester to the curtain shield airbag LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- Insert SST straight into the terminals of the connector.
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- SST
- 09843-18061
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832 or B1833 is not output.
- HINT:
- Codes other than DTC B1830, B1831, B1832, B1833 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||
| 3. CHECK CONNECTOR |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the floor wire connectors (on the curtain shield airbag LH side) are not damaged.
- OK:
- The lock button is not disengaged, or the claw of the lock is not deformed or damaged.
|
|
||||
| OK | |
| 4. CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH CIRCUIT) |
![]() ![]() |
Disconnect the connectors from the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Switch Condition
Specified Condition
C22-2 (ICL-) - Body ground
Ignition switch ON
Below 1 V
C22-1 (ICL+) - Body ground
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
C22-2 (ICL-) - C22-1 (ICL+)
Always
Below 1 Ω
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
C22-2 (ICL-) - C22-1 (ICL+)
Always
1 MΩ or higher
C22-2 (ICL-) - Body ground
C22-1 (ICL+) - Body ground
|
|
||||
| OK | |
| 5. CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() ![]() |
Connect the connectors to the curtain shield airbag LH and the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832 or B1833 is not output
- HINT:
- Codes other than DTC B1830, B1831, B1832, B1833 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||
| 6. CHECK CURTAIN SHIELD AIRBAG ASSEMBLY RH (CURTAIN SHIELD SQUIB RH) |
![]() ![]() |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the curtain shield airbag RH.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
- CAUTION:
- Never connect the tester to the curtain shield airbag RH (curtain shield squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- Insert SST straight into the terminals of the connector.
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832 or B1833 is not output.
- HINT:
- Codes other than DTC B1830, B1831, B1832 or B1833 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||
| 7. CHECK CONNECTOR |
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the floor wire connector (on the curtain shield airbag RH side) is not damaged.
- OK:
- The lock button is not disengaged, or the claw of the lock is not deformed or damaged.
|
|
||||
| OK | |
| 8. CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT) |
![]() ![]() |
Disconnect the connectors from the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Switch Condition
Specified Condition
C21-2 (ICR-) - Body ground
Ignition switch ON
Below 1 V
C21-1 (ICR+) - Body ground
Turn the ignition switch OFF.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
C21-2 (ICR-) - C21-1 (ICR+)
Always
Below 1 Ω
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
C21-2 (ICR-) - C21-1 (ICR+)
Always
1 MΩ or higher
C21-2 (ICR-) - Body ground
C21-1 (ICR+) - Body ground
|
|
||||
| OK | |
| 9. CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() ![]() |
Connect the connectors to the curtain shield airbag RH and the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch OFF.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832 or B1833 is not output
- HINT:
- Codes other than DTC B1830, B1831, B1832 or B1833 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||