2014 Hilux · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from Jun 2011

Oil pressureĀ 
Condition
Specified Condition
Idle
29 kPa (0.3 kgf/cm2, 4.2 psi) or more
3000 rpm
w/o EGR Cooler
160 to 490 kPa (1.6 to 5.0 kgf/cm2, 23 to 71 psi) or more
w/ EGR Cooler
245 kPa (2.5 kgf/cm2, 36 psi) or more
Oil pumpĀ 
Oil pump
Tip clearance
Standard
0.060 to 0.160 mm (0.0024 to 0.0063 in.)
Maximum
0.21 mm (0.0083 in.)
Body clearance
Standard
0.100 to 0.170 mm (0.0039 to 0.0066 in.)
Maximum
0.20 mm (0.0079 in.)
Side clearance
Standard
0.030 to 0.090 mm (0.0012 to 0.0036 in.)
Maximum
0.15 mm (0.0059 in.)
Pump drive shaft pulley
Thrust clearance
0.15 to 0.55 mm (0.0059 to 0.0217 in.)