2014 Hilux · Service Manual SECURITIES

CUSTOMIZE PARAMETERS

Removal / installation · Vehicles built from Jun 2011


1. CUSTOMIZE THEFT DETERRENT SYSTEM

HINT:
  1. The following items can be customized.
  2. During customize mode, the alarm control functions are disabled.
  3. During customize mode, the following wireless control functions are disabled: remote alarm function, automatic locking function, operation stop function and illuminated entry function.
  4. During customize mode, the ECU will not output lock/unlock signals.
  5. While in customize mode, if the key is inserted into the ignition key cylinder or a door is opened, customize mode will be canceled.

NOTICE:
  1. When the customer requests a change in a function, first make sure that the function can be customized.
  2. Record the current settings before customizing.

  1. Customizing with manual operation

    Display
    Default
    Content
    Setting
    Relevant ECU
    Shock sensor function
    Standard
    This function that adjusts sensitivity of the sensor that detects the intrusion.
    Standard, Low, Max Low, Sensor off
    Theft warning ECU assembly


2. CUSTOMIZE SHOCK SENSOR FUNCTION
  1. Customizing shock sensor function:

    1. Check that the following conditions are met.

      1. No key is in the ignition key cylinder.
      2. The theft deterrent system is in the disarmed state (when either condition below is met):
        1. All the doors are in the unlocked condition and the doors are locked and unlocked using the door control transmitter assembly.
        2. The key is inserted into the ignition key cylinder, the ignition switch is turned to ON then off, and then the key is removed.
      3. The driver side door is opened (the other doors are closed).

    2. Perform the following operation twice within 5 seconds:

      1. Insert the key into the ignition key cylinder, and then pull it out (ending with the key pulled out).

    3. Wait for 5 seconds.

    4. After completing the above step, press and hold down the lock switch and unlock switch on the door control transmitter assembly at the same time for over 3 seconds within 5 seconds.

    5. Check that the hazard warning lights flash once.

    6. After completing the lock and unlock switch operation, perform the following operation within 5 seconds.

      1. Press the lock switch on the door control transmitter assembly 4 times within 2 seconds.

    7. After completing the above step, press the unlock switch on door control transmitter assembly once within 2 seconds.

      HINT:
      After completing the above step, the present setting can be confirmed by pressing the unlock switch on the door control transmitter assembly once again.

    8. Check that the hazard warning lights flash 4 times.

    9. After completing the unlock switch operation, perform the following operations (mode select) within 10 seconds:

      1. Press the lock switch on door control transmitter assembly the number of times shown below depending on the desired function behavior to select the shock sensor function setting. Press the unlock switch on door lock transmitter once within 2 seconds of pressing the lock switch on door control transmitter assembly.

        HINT:
        If the lock switch on the door control transmitter is pressed 7 times or more, customize mode will be canceled.

      2. Pattern 1
        1. Shock sensor functioning: Sensor off
          1. Press the lock switch on door control transmitter assembly once.
        Pattern 2
        1. Shock sensor functioning: Max Low
          1. Press the lock switch on door control transmitter assembly twice.
        Pattern 3
        1. Shock sensor functioning: Low
          1. Press the lock switch on door control transmitter assembly 3 times.
        Pattern 4
        1. Shock sensor functioning: Standard
          1. Press the lock switch on door control transmitter assembly 4, 5 or 6 times.

    10. Check the response to the select mode.

      Response to Mode Select Operation
      Setting
      Hazard warning lights flash once
      Max Low, Low, Standard
      Hazard warning lights do not flash
      Sensor off

      HINT:
      The customization setting can be set again within 30 seconds of the hazard warning lights flashing.

    11. Check the response to the customize operation.

      Response to Customize Operation
      Setting
      Hazard warning lights flash once
      Sensor off
      Hazard warning lights flash twice
      Max Low
      Hazard warning lights flash 3 times
      Low
      Hazard warning lights flash 4, 5 or 6 times
      Standard

← HOW TO PROCEED WITH TROUBLESHOOTING (from Aug 2012)PROBLEM SYMPTOMS TABLE (from Jun 2011) →