FUNCTION
An L-type SFI system directly detects the intake air mass with a hot wire type intake mass air flow meter sub-assembly.
An independent injection system (in which fuel is injected once into each cylinder for each two revolutions of the crankshaft) is used.
There are two types of injections (synchronous and non-synchronous):
The synchronous injection, in which corrections based on the signals from the sensors are added to the basic injection time, so that injection always occurs at the same position.
The non-synchronous injection, in which injection is effected by detecting the requests from the signals of the sensors regardless of the crankshaft angle.
This system performs group injection when the engine coolant temperature is extremely low and the engine speed is low.
Injection volume correction is performed depending on the ethanol concentration of the fuel in the fuel main tank.