Home › Engine / Hybrid System › 2TR-FE EMISSION CONTROL › EMISSION CONTROL SYSTEM
NM1840EF _51 Engine / Hybrid System _010310 2TR-FE EMISSION CONTROL _0055235 EMISSION CONTROL SYSTEM DE DETAILS F

2TR-FE EMISSION CONTROL  EMISSION CONTROL SYSTEM  DETAILS  AIR INJECTION CONTROL DRIVER  


OPERATION


a.

The air injection control driver is a non-contact type relay that uses semiconductors. Activated by the ECM, this driver actuates the air pump and the air switching valve.


b.

The air injection control driver also detects failures in the input and output circuits at the air injection control driver and transmits the failure status to the ECM via duty cycle signals.


c.

For details of the control of the air injection control driver, see the following system chart:

W102664
2.24,0.833 3.458,1.458 1.219,0.625 10 false Air Pump Actuation Request 2.26,1.802 3.458,2.49 1.198,0.688 10 false Air Switching Valve Actuation Request 2.354,3.188 3.531,3.542 1.177,0.354 10 false Duty Cycle Signal 1.927,0.615 2.292,0.813 0.365,0.198 10 false AIRP 1.927,1.604 2.292,1.802 0.365,0.198 10 false AIRV 1.927,2.49 2.292,2.688 0.365,0.198 10 false AIDI 3.708,2.479 4.073,2.677 0.365,0.198 10 false DI 3.635,1.552 4,1.75 0.365,0.198 10 false SIV 3.615,0.573 3.979,0.771 0.365,0.198 10 false SIP 5.302,1.438 5.969,1.813 0.667,0.375 10 false Air Pump 5.052,2.927 6.302,3.292 1.25,0.365 10 false Air Switching Valve 4.917,2.042 5.198,2.323 0.281,0.281 10 false VV 4.938,1.083 5.219,1.365 0.281,0.281 10 false VP 4,1.313 4.729,2.313 0.729,1 10 false Air Injection Control Driver 1.198,1.604 1.594,1.927 0.396,0.323 10 false ECM

DI Terminal Output
Condition AIRP AIRV Output (Duty Cycle Signal)
Open circuit in line between AIDI and DI terminals. - -
W112594
0.104,0.531 0.563,0.729 0.458,0.198 8 false GND

Failure in line between ECM terminals and air injection control driver. - -
W112594
0.104,0.531 0.563,0.729 0.458,0.198 8 false GND

Output failure at air injection control driver. (Failure in air pump actuation circuit) - -
W112596
0.094,0.573 0.552,0.771 0.458,0.198 8 false GND 0.833,0.104 1.292,0.302 0.458,0.198 8 false 200 ms 1.667,0.083 2.198,0.323 0.531,0.24 8 false Duty 20%

Output failure at air injection control driver. (Failure in air switching valve actuation circuit) - -
W112597
0.094,0.573 0.552,0.771 0.458,0.198 8 false GND 1.677,0.073 2.198,0.333 0.521,0.26 8 false Duty 40%

Overheat failure of air injection control driver. - -
W112598
0.094,0.583 0.469,0.74 0.375,0.156 8 false GND 1.667,0.073 2.208,0.323 0.542,0.25 8 false Duty 60%

Normal On On
W112600
0.094,0.583 0.469,0.74 0.375,0.156 8 false GND 1.656,0.083 2.198,0.323 0.542,0.24 8 false Duty 80%

Off Off
W112595
0.083,0.417 0.458,0.573 0.375,0.156 8 false GND

On Off
Off On