Home › Drivetrain › A750F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM › from 2012.04
NM1840EF _52 Drivetrain _010339 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0055269 AUTOMATIC TRANSMISSION SYSTEM DE DETAILS F

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  DETAILS  SHIFT SOLENOID VALVE  


CONSTRUCTION


a.

The shift solenoid valve DSL (S1) and shift solenoid valve S4 (SR) are 3-way solenoid valves.


b.

The No. 3 transmission solenoid assembly (S2) uses a 2-way solenoid valve.


c.

A filter is provided at the tip of the solenoid valve to further improve operational reliability.

Shift Solenoid Valve S1
X105631
1.292,0.99 1.125,1.219 true 0.958,1.229 1.229,1.448 0.271,0.219 10 false *1 4.917,1.458 5.188,1.677 0.271,0.219 10 false *b 2.021,1.458 2.292,1.677 0.271,0.219 10 false *a
*1 Filter - -
*a Off Condition *b On Condition
V100135

Line Pressure
V100136

Control Pressure
V100137

Drain - -


Shift Solenoid Valve S2
X105632
1.542,0.927 1.375,1.156 true 1.229,1.188 1.5,1.406 0.271,0.219 10 false *1 5.125,1.448 5.396,1.667 0.271,0.219 10 false *b 2.229,1.448 2.5,1.667 0.271,0.219 10 false *a
*1 Filter - -
*a Off Condition *b On Condition
V100135

Line Pressure
V100136

Control Pressure


Shift Solenoid Valve SR
X105633
1.292,0.948 1.115,1.177 true 1.021,1.219 1.292,1.438 0.271,0.219 10 false *1 4.938,1.448 5.208,1.667 0.271,0.219 10 false *b 2.042,1.448 2.313,1.667 0.271,0.219 10 false *a
*1 Filter - -
*a Off Condition *b On Condition
V100135

Line Pressure
V100136

Control Pressure
V100137

Drain - -



d.

In order to provide a hydraulic pressure that is proportional to the current that flows to the solenoid coil, the shift solenoid valves SL1 and SL2 linearly control the clutch pressure based on the signals they receive from the ECM or TCM.

X102203
2.198,0.219 2.01,0.219 2.01,0.219 2.01,0.573 true 3.208,0.188 2.927,0.188 2.927,0.188 2.927,0.531 true 1.229,0.188 1.563,0.188 1.563,0.188 1.646,0.75 true 4.292,0.167 4.917,0.792 0.625,0.625 10 false Hydraulic Pressure 5.896,1.333 6.406,1.615 0.51,0.281 10 false Current 0.448,0.115 1.219,0.396 0.771,0.281 10 false Spool Valve 2.229,0.125 2.677,0.406 0.448,0.281 10 false Sleeve 3.24,0.094 4.188,0.375 0.948,0.281 10 false Solenoid Coil 1.25,1.438 3.344,1.781 2.094,0.344 10 false Shift Solenoid Valves (SL1, SL2)


e.

In order to provide a hydraulic pressure that is proportional to the current that flows to the solenoid coil, the line pressure control solenoid assembly (SLT) linearly controls the line pressure based on the signals it receives from the ECM or TCM.

X102204
2.083,0.208 1.896,0.208 1.896,0.208 1.896,0.76 true 3.198,0.219 2.917,0.219 2.917,0.219 2.917,0.719 true 1.24,0.208 1.615,0.208 1.615,0.208 1.615,0.885 true 4.313,0.167 4.917,0.771 0.604,0.604 10 false Hydraulic Pressure 5.906,1.323 6.417,1.604 0.51,0.281 10 false Current 0.458,0.125 1.229,0.406 0.771,0.281 10 false Spool Valve 2.104,0.104 2.552,0.385 0.448,0.281 10 false Sleeve 3.24,0.115 4.188,0.396 0.948,0.281 10 false Solenoid Coil 0.771,1.365 3.969,1.708 3.198,0.344 10 false Line Pressure Control Solenoid Assembly (SLT)


f.

In order to provide a hydraulic pressure that is proportional to the current that flows to the solenoid coil, the lock-up control solenoid assembly (SLU) linearly controls the lock-up clutch engagement pressure based on the signals it receives from the ECM or TCM.

X102205
3.208,0.208 2.917,0.208 2.917,0.208 2.917,0.74 true 2.042,0.24 1.854,0.24 1.854,0.24 1.854,0.813 true 1.24,0.208 1.49,0.208 1.49,0.208 1.729,0.938 true 4.292,0.167 4.917,0.76 0.625,0.594 10 false Hydraulic Pressure 5.906,1.333 6.406,1.615 0.5,0.281 10 false Current 3.271,0.125 4.219,0.406 0.948,0.281 10 false Solenoid Coil 0.458,0.115 1.229,0.396 0.771,0.281 10 false Spool Valve 2.083,0.156 2.531,0.438 0.448,0.281 10 false Sleeve 1.031,1.385 3.729,1.729 2.698,0.344 10 false Lock-up Control Solenoid Assembly (SLU)

Function of Shift Solenoid Valves
Shift Solenoid Valve Function
S1 Switches the 2-3 shift valve.
S2 Switches the 1-2 shift valve and the 3-4 shift valve.
SR Switches the clutch apply control valve.
SL1
·

C1 clutch pressure control

·

Accumulator back pressure control


SL2 B1, B2 and B4 brake pressure control
SLT
·

Line pressure control

·

Accumulator back pressure control


SLU
·

Lock-up clutch pressure control

·

Accumulator back pressure control