FUNCTION OF MAIN COMPONENTS
The manual heater, manual air conditioning system and automatic air conditioning system consist of the following parts:
| Component | Function |
|---|---|
| Air Conditioning Control Assembly*1, *2 | Allows operation and adjustment of the air conditioning system via the switches. |
| Integration Panel Sub-assembly*3 | |
| Air Conditioning Amplifier Assembly | Transmits and receives data to and from the switches and sensors. |
| Cooler Compressor Assembly*2, *3 | A fixed displacement cooler compressor assembly is used. |
| Cooler Condenser Assembly*2, *3 | A Multi-Flow-III (MF-III) sub-cool condenser*4 or Multi-Flow-IV (MF-IV) sub-cool condenser*5 is used to improve heat exchange efficiency. |
| Heater Radiator Unit Sub-assembly | A Straight Flow Aluminum-II (SFA-II) heater radiator is used for compactness and high performance. |
| Blower with Fan Motor Sub-assembly | High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly. |
| No. 1 Cooler Evaporator Sub-assembly*2, *3 | A Revolutionary super-slim Structure (RS) is used for compactness. |
| No. 1 Cooler Thermistor*2, *3 | Detects the temperature of the cool air past the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly. |
| Cooler Expansion Valve*2, *3 | Sprays the refrigerant in an atomized form. |
| Cooler Thermistor (Ambient Temperature Sensor)*3 | Detects ambient temperature and outputs it to the air conditioning amplifier assembly via the combination meter assembly. |
| Cooler Thermistor (Room Temperature Sensor)*3 | Detects room temperature and outputs it to the air conditioning amplifier assembly. |
| Cooler Thermistor (Solar Sensor)*3 | Detects the changes in the amount of solar energy and outputs them to the air conditioning amplifier assembly. |
| Damper Servo Sub-assembly*3 | Receives the input of the operation signals from the fresh-air/recirculation selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the fresh-air/recirculation damper. |
| Mode Damper Servo Sub-assembly*3 | Receives the input of the operation signals from the mode selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the mode damper. |
| Air Mix Control Servo Motor*3 | Operates the motor to open and close the air mix damper upon receiving the input of the operation signals from the temperature setting dial via the air conditioning amplifier assembly, or when the system is operating under auto control. |
| Clean Air Filter | Removes other particles to provide a comfortable interior space. |
| ECM | Receives the signals from the engine coolant temperature sensor and transmits them to the air conditioning amplifier assembly. |
| Air Conditioning Pressure Sensor*2, *3 | Mounted on the high-pressure pipe, this sensor controls the compressor assembly. |
*1: Models with manual heater system
*2: Models with manual air conditioning system
*3: Models with automatic air conditioning system
*4: TASA made
*5: TMT made
SYSTEM CONTROL
The air conditioning system uses the following controls:
| Control | Outline | |
|---|---|---|
| Outlet Air Temp. Control | Air Mix Damper Control | This function provisionally calculates the required outlet air temperature through an arithmetic circuit in the air mix damper using the output signals from various sensors, and adjusts the value in accordance with signals from the evaporator temperature sensor and water temperature sensor. It then determines the appropriate air mix damper opening angle in accordance with the temperature control switch setting. |
| Blower Control | Manual Control | Sets the blower speed in accordance with the operation of the blower switch. |
| Automatic Control | Time-Lagged Air Flow Control:
2 types of time-lagged air flow control (in accordance with the temperature detected by the evaporator temperature sensor) help prevent hot air from being emitted from the FACE or BI-LEVEL vent. |
|
| Sunlight Air Flow Control:
Controls the blower speed in accordance with the intensity of the sunlight when the air outlet is in FACE or BI-LEVEL. The blower speed can be adjusted in response to the signal received from the solar sensor. |
||
| Air Outlet Control | Manual Control | Changes the air outlet in accordance with the selected position of the mode select switch. |
| Automatic Control | Mode Damper Switching Servomotor Control:
When the AUTO switch of the heater control panel has been turned on, automatic control causes the mode servomotor to rotate to a desired position in accordance with the target damper opening, which is based on the calculation of the outlet air temperature. (On the models with the automatic cooler, this function switches the damper to FACE or BI-LEVEL.) |
|
| Compressor Control | When the DEF mode switch is turned on, the magnetic clutch relay is activated automatically to engage the compressor. Also, when the blower is turned off, and the front defroster switch is turned on, the blower will turn on in the automatic control condition. | |
| Self-diagnosis | Checks the indicator, sensor and actuator in accordance with operation of the heater control panel switches, and then a Diagnostic Trouble Code (DTC) is displayed on the LCD portion to indicate if there is a malfunction or not. | |
DIAGNOSIS
Diagnostic Trouble Code (DTC)
The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the air conditioning system memory in the form of DTCs. For details, refer to the Repair Manual.