CONSTRUCTION
An oxidation catalyst is used to clean the exhaust gas particulates, HC, and CO. The table below describes the location of the catalyst:
| Emission Regulations or Destination | Location of Catalyst | |
|---|---|---|
| Integrated with Front Exhaust Pipe | Below Exhaust Manifold | |
| EURO 5 | ○ | ○ |
| EURO 4 | ○ | - |
| EURO 3 | - | ○ |
| EURO 1 | - | - |
| High Altitude Countries | ○ | - |
| Non-compliant with Emission Regulation
(Except High Altitude Countries) |
- | - |
| *A | Models Compliant with EURO 5 Emission Regulations | *B | Models Compliant with EURO 4 Emission Regulations |
| *C | Models with Wastegate Valve Type Turbocharger | *D | Models with Variable Nozzle Vane Type Turbocharger |
| *E | Models for High Altitude Countries | *F | Models Compliant with EURO 3 Emission Regulations |
| *1 | Turbine Outlet Elbow | *2 | No. 2 Turbine Outlet Elbow |
| *3 | Oxidation Catalyst | *4 | Front Exhaust Pipe Assembly |
| *5 | Exhaust Manifold Converter Sub-assembly | - | - |