RM1840EF
_V1
General
_009566
SPECIFICATIONS
_0051982
1KD-FTV INTAKE / EXHAUST
F
SPECIFICATIONS 1KD-FTV INTAKE / EXHAUST SERVICE DATA
INTAKE MANIFOLD
| Vacuum switching valve (for Swirl Control Valve)
|
Standard resistance
|
Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
33 to 39 Ω
|
| 1 - Body ground
|
20°C (68°F)
|
10 kΩ or higher
|
| 2 - Body ground
|
TURBOCHARGER
| Turbocharger pressure
|
Condition
|
Specified Condition
|
Engine speed
(approximately 4600 rpm)
|
15 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)
|
| Axial play of turbine shaft
|
Maximum axial play
|
0.11 mm (0.00433 in.)
|
| Radial play of turbine shaft
|
Maximum radial play
|
0.112 mm (0.00440 in.)
|
EXHAUST PIPE
| Compression spring
|
Minimum length
|
40 mm (1.57 in.)
|