Home › General › SPECIFICATIONS › 1KD-FTV INTAKE / EXHAUST › 2011.10–2012.04
RM1840EF _V1 General _009566 SPECIFICATIONS _0051982 1KD-FTV INTAKE / EXHAUST F

SPECIFICATIONS  1KD-FTV INTAKE / EXHAUST  SERVICE DATA  


INTAKE MANIFOLD
Vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 20°C (68°F) 10 kΩ or higher
2 - Body ground

TURBOCHARGER
Turbocharger pressure Condition Specified Condition
Engine speed
(approximately 4600 rpm)
15 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)
Axial play of turbine shaft Maximum axial play 0.11 mm (0.00433 in.)
Radial play of turbine shaft Maximum radial play 0.112 mm (0.00440 in.)

EXHAUST PIPE
Compression spring Minimum length 40 mm (1.57 in.)