Home › General › SPECIFICATIONS › 1KD-FTV INTAKE / EXHAUST › from 2012.04
RM1840EF _V1 General _009566 SPECIFICATIONS _0051982 1KD-FTV INTAKE / EXHAUST F

SPECIFICATIONS  1KD-FTV INTAKE / EXHAUST  SERVICE DATA  


INTAKE SYSTEM (w/ Glow Plug Controller)
Turbocharger pressure Condition Specified Condition
Engine speed
(approximately 4450 to 4750 rpm)
5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi)
Manifold absolute pressure sensor Condition Tester Connection Specified Condition
ECM output voltage 3 VC (+) - 1 E (-) 4.75 to 5.25 V
Applied vacuum - -
13.3 kPa (100 mmHg, 3.94 in.Hg) for DPF:
C114-5 (PIM +) - C114-14 (E2 -)
for i-ART:
C167-12 (PIM +) - C167- 6 (EPIM -)
0.8 to 1.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg) 0.5 to 1.0 V
40 kPa (300 mmHg, 11.81 in.Hg) 0.3 to 0.9 V
Applied pressure - -
19.6 kPa (0.20 mmHg, 2.84 in.Hg) for DPF:
C114-5 (PIM +) - C114-14 (E2 -)
for i-ART:
C167-12 (PIM +) - C167- 6 (EPIM -)
1.0 to 1.7 V
39.2 kPa (0.40 mmHg, 5.69 in.Hg) 1.3 to 1.9 V
58.8 kPa (0.60 mmHg, 8.53 in.Hg) 1.5 to 2.2 V
78.5 kPa (0.80 mmHg, 11.4 in.Hg) 1.8 to 2.4 V
98.0 kPa (1.00 mmHg, 14.2 in.Hg) 2.1 to 2.7 V

INTAKE SYSTEM (w/o Glow Plug Controller)
Turbocharger pressure Condition Specified Condition
Engine speed
(approximately 4600 rpm)
15 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)

INTAKE MANIFOLD (w/o Glow Plug Controller)
Vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 20°C (68°F) 10 kΩ or higher
2 - Body ground

VACUUM SWITCHING VALVE (for DPF)
No. 1 vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 20°C (68°F) 10 kΩ or higher
2 - Body ground

VACUUM SWITCHING VALVE (for i-ART)
No. 1 vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 20°C (68°F) 10 kΩ or higher
2 - Body ground
No. 2 vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 20°C (68°F) 10 kΩ or higher
2 - Body ground

TURBOCHARGER
Axial play of turbine shaft Maximum axial play 0.11 mm (0.00433 in.)
Radial play of turbine shaft Maximum radial play 0.112 mm (0.00440 in.)

EXHAUST PIPE (w/ DPF)
Compression spring Minimum length 43 mm (1.69 in.)

EXHAUST PIPE (w/o DPF)
Compression spring Minimum length 40 mm (1.57 in.)