Home › Engine / Hybrid System › 2KD-FTV ENGINE CONTROL › INTAKE AIR TEMPERATURE SENSOR(w/o DPF)
RM1840EF _51 Engine / Hybrid System _009568 2KD-FTV ENGINE CONTROL _0052063 INTAKE AIR TEMPERATURE SENSOR(w/o DPF) G

2KD-FTV ENGINE CONTROL  INTAKE AIR TEMPERATURE SENSOR(w/o DPF)  INSPECTION  


PROCEDURE

Hide 1.INSPECT INTAKE AIR TEMPERATURE SENSOR

A253476
5.469,1.229 5.771,0.854 false 1.656,1.052 1.74,1.052 1.74,1.052 1.885,1.198 false 2.177,1.042 2.104,1.042 2.104,1.042 1.948,1.198 false 4.281,0.063 4.573,0.24 0.292,0.177 10 false *1 5.802,0.677 6.094,0.875 0.292,0.198 10 false *3 4.521,0.177 4.844,0.385 0.323,0.208 8 false 30 4.521,0.323 4.844,0.531 0.323,0.208 8 false 20 4.521,0.531 4.844,0.74 0.323,0.208 8 false 10 4.521,0.792 4.844,1 0.323,0.208 8 false 5 4.521,0.958 4.844,1.167 0.323,0.208 8 false 3 4.521,1.083 4.844,1.292 0.323,0.208 8 false 2 4.521,1.302 4.844,1.51 0.323,0.208 8 false 1 4.469,1.844 4.792,2.052 0.323,0.208 8 false 0.2 4.469,1.708 4.792,1.917 0.323,0.208 8 false 0.3 4.469,1.604 4.792,1.813 0.323,0.208 8 false 0.5 4.469,2.073 4.792,2.281 0.323,0.208 8 false 0.1 4.969,2.354 5.167,2.49 0.198,0.135 8 false 0 5.177,2.354 5.49,2.677 0.313,0.323 8 false 20 5.406,2.5 5.76,2.667 0.354,0.167 8 false (104) 5.698,2.354 5.979,2.49 0.281,0.135 8 false 60 5.969,2.344 6.219,2.5 0.25,0.156 8 false 80 4.688,2.354 4.99,2.5 0.302,0.146 8 false -20 6.76,2.281 7.031,2.448 0.271,0.167 10 false *2 1.563,0.948 1.792,1.135 0.229,0.188 10 false 1 2.208,0.958 2.438,1.167 0.229,0.208 10 false 2 4.271,0.229 4.583,0.406 0.313,0.177 10 false kΩ 6.635,2.469 7.073,2.646 0.438,0.177 10 false °C(°F) 4.938,2.5 5.208,2.656 0.271,0.156 8 false (32) 5.177,2.5 5.469,2.656 0.292,0.156 8 false (68) 5.417,2.354 5.677,2.49 0.26,0.135 8 false 40 5.688,2.5 6.021,2.646 0.333,0.146 8 false (140) 5.958,2.5 6.396,2.667 0.438,0.167 8 false (176) 6.25,2.354 6.615,2.49 0.365,0.135 8 false 100 6.24,2.5 6.625,2.667 0.385,0.167 8 false (212) 4.698,2.5 5.104,2.656 0.406,0.156 8 false (-4)
*1 Resistance *2 Temperature
*3 Acceptable Range - -


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.21 to 2.65 kΩ


If the result is not as specified, replace the intake air temperature sensor.

NOTICE:

When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.