Home › Engine / Hybrid System › 2KD-FTV ENGINE CONTROL › INTAKE AIR TEMPERATURE SENSOR(w/ DPF) › from 2012.04
RM1840EF _51 Engine / Hybrid System _009568 2KD-FTV ENGINE CONTROL _0052071 INTAKE AIR TEMPERATURE SENSOR(w/ DPF) G

2KD-FTV ENGINE CONTROL  INTAKE AIR TEMPERATURE SENSOR(w/ DPF)  INSPECTION  


PROCEDURE

Hide 1.INSPECT INTAKE AIR TEMPERATURE SENSOR

a.
A221977
1.792,2.646 2.146,2.073 2.146,2.073 2.24,2.073 false 1.792,0.479 1.646,0.375 1.646,0.375 1.615,0.375 false 1.865,0.479 2.021,0.375 2.021,0.375 2.042,0.375 false 0.083,2.469 0.281,2.646 0.198,0.177 10 false *1 0.115,0.135 0.313,0.313 0.198,0.177 10 false *a 1.917,4.427 2.115,4.615 0.198,0.188 10 false *2 2.292,1.979 2.469,2.177 0.177,0.198 10 false *3 0.271,1.438 0.573,1.667 0.302,0.229 10 false 30 0.271,1.583 0.573,1.781 0.302,0.198 10 false 20 0.271,1.854 0.563,2.063 0.292,0.208 10 false 10 0.354,2.135 0.583,2.344 0.229,0.208 10 false 5 0.354,2.333 0.583,2.542 0.229,0.208 10 false 3 0.354,2.5 0.573,2.708 0.219,0.208 10 false 2 0.354,2.719 0.563,2.938 0.208,0.219 10 false 1 1.49,0.271 1.604,0.479 0.115,0.208 10 false 1 2.052,0.271 2.167,0.479 0.115,0.208 10 false 2 0.24,3.323 0.583,3.5 0.344,0.177 10 false 0.2 0.24,3.167 0.604,3.354 0.365,0.188 10 false 0.3 0.24,2.969 0.542,3.146 0.302,0.177 10 false 0.5 0.24,3.615 0.573,3.802 0.333,0.188 10 false 0.1 1.104,4 1.198,4.188 0.094,0.188 10 false 0 1.469,4 1.646,4.177 0.177,0.177 10 false 20 1.865,3.99 2.052,4.156 0.188,0.167 10 false 40 2.25,3.99 2.438,4.167 0.188,0.177 10 false 60 2.646,4 2.833,4.167 0.188,0.167 10 false 80 2.979,4 3.24,4.177 0.26,0.177 10 false 100 0.604,4 0.833,4.156 0.229,0.156 10 false -20 1.021,4.188 1.292,4.417 0.271,0.229 10 false (32) 1.417,4.188 1.677,4.396 0.26,0.208 10 false (68) 1.771,4.188 2.135,4.375 0.365,0.188 10 false (104) 2.177,4.188 2.531,4.396 0.354,0.208 10 false (140) 2.563,4.188 2.917,4.417 0.354,0.229 10 false (176) 2.958,4.188 3.333,4.375 0.375,0.188 10 false (212) 0.615,4.188 0.854,4.396 0.24,0.208 10 false (-4)
*1 Resistance kΩ
*2 Temperature °C(°F)
*3 Acceptable Range
*a Component without harness connected
(Intake Air Temperature Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.21 to 2.65 kΩ


NOTICE:

When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.


If the result is not as specified, replace the intake air temperature sensor.