Home › Engine / Hybrid System › 2KD-FTV ENGINE CONTROL › MANIFOLD ABSOLUTE PRESSURE SENSOR(w/ DPF) › from 2012.04
RM1840EF _51 Engine / Hybrid System _009568 2KD-FTV ENGINE CONTROL _0052072 MANIFOLD ABSOLUTE PRESSURE SENSOR(w/ DPF) G

2KD-FTV ENGINE CONTROL  MANIFOLD ABSOLUTE PRESSURE SENSOR(w/ DPF)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR

a.

Inspect the power source voltage.

i.

Disconnect the manifold absolute pressure sensor connector.


ii.
A301320
1.375,0.927 1.5,0.927 1.5,0.927 1.677,1.073 false 2.052,1.125 2.208,1.229 2.208,1.229 2.313,1.229 false 0.073,0.042 0.385,0.24 0.313,0.198 10 *a 0.969,0.854 1.438,1.052 0.469,0.198 10 1 E (-) 2.354,1.156 3.042,1.375 0.688,0.219 10 3 VC (+)
*a Front view of wire harness connector
(to Manifold Absolute Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
3 (VC) - 1 (E) Ignition switch ON 4.75 to 5.25 V


If the result is not as specified, inspect the wire harness or ECM (See page Engine / Hybrid System>2KD-FTV ENGINE CONTROL>ECD SYSTEM(for DPF)>TERMINALS OF ECM).


iii.

Connect the manifold absolute pressure sensor connector.



b.

Check the power supply.

i.

Turn the ignition switch to ON.


ii.

Disconnect the vacuum hose from the manifold absolute pressure sensor.


iii.
A272523
1.729,0.469 2.219,0.698 0.49,0.229 1.896,1.146 1.427,1.75 1.427,1.75 1.427,1.823 false 2.031,1.219 2.542,1.75 2.542,1.75 2.542,1.823 false 1.146,1.865 1.646,2.052 0.5,0.188 10 false 5 (PIM) 0.125,0.094 0.406,0.26 0.281,0.167 10 false *a 2.281,1.865 2.781,2.042 0.5,0.177 10 false 14 (E2) 1.802,0.5 2.167,0.698 0.365,0.198 10 false C114
*a Component without harness connected
(ECM)
V100135

Vacuum


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C114-5 (PIM) - C114-14 (E2) -13.3 kPa (100 mmHg, 3.94 in.Hg) 0.0 to 0.3 V
-26.6 kPa (199 mmHg, 7.85 in.Hg) 0.1 to 0.4 V
-40 kPa (300 mmHg, 11.81 in.Hg) 0.3 to 0.6 V


HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.


iv.
A272524
1.729,0.531 2.219,0.76 0.49,0.229 1.896,1.208 1.427,1.813 1.427,1.813 1.427,1.896 false 2.031,1.281 2.542,1.813 2.542,1.813 2.542,1.896 false 2.365,3.542 2.74,2.875 2.74,2.875 2.854,2.875 true 1.146,1.927 1.646,2.125 0.5,0.198 10 false 5 (PIM) 0.135,0.146 0.323,0.313 0.188,0.167 10 false *a 2.271,1.927 2.76,2.115 0.49,0.188 10 false 14 (E2) 1.802,0.573 2.167,0.885 0.365,0.313 10 false C114 2.875,2.781 3.188,2.948 0.313,0.167 10 false SST
*a Component without harness connected
(ECM)
V100135

Pressure


Using SST, measure the voltage according to the value(s) in the table below.

SST
09992-00242  

Standard Voltage:
Tester Connection Condition Specified Condition
C114-5 (PIM) - C114-14 (E2) 19.6 kPa (0.20 kgf/cm2, 2.84 psi) 0.1 to 0.4 V
39.2 kPa (0.40 kgf/cm2, 5.69 psi) 0.3 to 0.6 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi) 0.5 to 0.8 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi) 0.7 to 1.1 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi) 0.9 to 1.3 V


HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.