Home › Engine / Hybrid System › 2TR-FBE ENGINE CONTROL › HEATED OXYGEN SENSOR
RM1840EF _51 Engine / Hybrid System _009571 2TR-FBE ENGINE CONTROL _0052122 HEATED OXYGEN SENSOR G

2TR-FBE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

a.

Check the resistance.

i.
A112088
1.26,0.76 0.771,0.76 true 2.667,0.76 2.146,0.76 true 0.771,1.667 0.896,1.667 0.896,1.667 1.271,1.448 true 0.49,0.656 0.792,0.865 0.302,0.208 10 false +B 2.771,0.667 3.229,0.917 0.458,0.25 10 false HT1A 0.5,1.563 0.844,1.771 0.344,0.208 10 false E2 0.042,0 0.219,0.167 0.177,0.167 10 false *a
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (HT1A) - 2 (+B) 20°C (68°F) 5 to 10 Ω
1 (HT1A) - 4 (E2) Always 10 kΩ or higher


If the result is not as specified, replace the heated oxygen sensor.