Home › Engine / Hybrid System › 1GR-FE ENGINE CONTROL › HEATED OXYGEN SENSOR › from 2012.04
RM1840EF _51 Engine / Hybrid System _009572 1GR-FE ENGINE CONTROL _0052140 HEATED OXYGEN SENSOR G

1GR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT HEATED OXYGEN SENSOR

a.
A252947
1.333,0.885 1.073,0.438 1.073,0.438 1.01,0.438 true 1.344,1.281 0.979,1.031 0.979,1.031 0.906,1.031 true 2,0.948 2.281,0.479 2.281,0.479 2.344,0.479 true 2.385,0.417 2.927,0.583 0.542,0.167 10 false HT1B*A 2.375,0.656 2.896,0.844 0.521,0.188 10 false HT2B*B 0.052,0.052 0.25,0.208 0.198,0.156 10 false *a 0.75,0.323 0.979,0.531 0.229,0.208 10 false +B 0.646,0.906 0.865,1.094 0.219,0.188 10 false E2
*A for Bank 1
*B for Bank 2
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT1B) - 4 (E2) Always 10 kΩ or higher


Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT2B) - 4 (E2) Always 10 kΩ or higher


If the result is not as specified, replace the heated oxygen sensor.