Home › Engine / Hybrid System › 2TR-FBE ENGINE MECHANICAL › DRIVE BELT › 2011.10–2012.10
RM1840EF _51 Engine / Hybrid System _009576 2TR-FBE ENGINE MECHANICAL _0052194 DRIVE BELT A

2TR-FBE ENGINE MECHANICAL  DRIVE BELT  INSTALLATION  


PROCEDURE

Hide 1.INSTALL TENSIONER PULLEY

NOTICE:

Perform the following procedure when it is necessary to replace the tensioner pulley.


HINT:

The tensioner pulley service kit consists of a bolt, nut, dust seal and tensioner pulley.


a.
A302380
2.406,0.25 2.313,0.135 2.313,0.135 2.146,0.135 false 1.698,1.469 1.927,1.469 false 0.552,1.031 0.552,1.438 false 0.458,1.49 0.771,1.646 0.313,0.156 10 false *1 1.948,0.031 2.26,0.188 0.313,0.156 10 false *2 1.979,1.365 2.292,1.521 0.313,0.156 10 false *3
*1 Bolt
*2 Tensioner Pulley
*3 Dust Seal
V100135

Front


Install the dust seal and bolt to the tensioner pulley as shown in the illustration.

NOTICE:
·

The dust seal must be oriented correctly when installed. If the dust seal is installed incorrectly, the bearing may be damaged.

·

Do not touch the seal surface of the bearing.



HINT:

Be sure to use the bolt and nut from the service kit.



b.
A303021
2.99,2.667 2.667,3.01 2.667,3.01 2.438,3.01 false 2.219,0.563 1.448,0.271 1.448,0.271 1.188,0.271 true 1.01,0.156 1.323,0.313 0.313,0.156 10 false *1 2.25,2.906 2.563,3.063 0.313,0.156 10 false *a
*1 Tensioner Arm
*a Flat Face


Set the nut in place on the tensioner arm so that the flat face of the nut contacts the tensioner arm as shown in the illustration.

NOTICE:

Make sure the nut is not installed backwards.



c.

Tighten the bolt by hand until the flange of the bolt contacts the dust seal and the tensioner pulley is fixed in place.

NOTICE:
·

Perform this procedure while holding the nut in place on the tensioner arm so that it does not fall.

·

Do not use any tools.




d.

Tighten the bolt.

Torque:
47 N*m (479 kgf*cm, 35 ft.*lbf)


e.

Install a new O-ring and the engine oil level dipstick guide with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


f.

Install the engine oil level dipstick.


Hide 2.INSTALL FAN AND GENERATOR V BELT

a.

Install the fan and generator V belt to all the pulleys except the V-ribbed belt tensioner pulley.

A302381
3.271,1.01 3.208,0.813 3.208,0.813 3.073,0.813 false 3.708,1.052 3.844,0.604 3.844,0.604 4,0.604 true 4.271,0.927 4.406,0.479 4.406,0.479 4.563,0.479 true 4.115,1.344 4.5,1.344 true 4.458,1.667 4.635,1.667 true 4.104,1.656 4.229,2.094 4.229,2.094 4.365,2.094 true 3.781,1.854 3.781,2.167 true 3.5,1.531 3.167,1.813 3.167,1.813 3.01,1.813 true 5.333,0.969 5.271,0.771 5.271,0.771 5.135,0.771 false 5.813,1.01 5.948,0.563 5.948,0.563 6.104,0.563 true 6.396,0.917 6.531,0.469 6.531,0.469 6.688,0.469 true 5.583,1.5 5.25,1.781 5.25,1.781 5.094,1.781 true 5.865,1.823 5.865,2.135 true 6.198,1.281 6.583,1.281 true 3.063,0.115 3.375,0.271 0.313,0.156 10 false *A 5.188,0.125 5.5,0.281 0.313,0.156 10 false *B 2.906,0.698 3.219,0.854 0.313,0.156 10 false *1 4.073,0.5 4.344,0.688 0.271,0.188 10 false *2 4.615,0.375 4.927,0.531 0.313,0.156 10 false *3 4.563,1.25 4.885,1.406 0.323,0.156 10 false *4 2.823,1.708 3.135,1.865 0.313,0.156 10 false *5 3.698,2.198 4.01,2.354 0.313,0.156 10 false *6 4.427,1.99 4.74,2.146 0.313,0.156 10 false *7 4.688,1.563 5,1.719 0.313,0.156 10 false *8 4.99,0.667 5.302,0.823 0.313,0.156 10 false *1 6.156,0.469 6.427,0.656 0.271,0.188 10 false *2 6.771,0.375 7.083,0.531 0.313,0.156 10 false *3 6.635,1.198 6.948,1.354 0.313,0.156 10 false *4 5.781,2.167 6.094,2.323 0.313,0.156 10 false *6 4.927,1.677 5.24,1.833 0.313,0.156 10 false *5
*A w/ Air Conditioning System *B w/o Air Conditioning System
*1 Generator *2 Idler Pulley
*3 Vane Pump *4 Fan Pulley
*5 Tensioner Pulley *6 Crankshaft Pulley
*7 No. 1 Idler Pulley *8 Cooler Compressor



b.

Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward, and then install the fan and generator V belt to the tensioner pulley.

NOTICE:
·

The backside of the fan and generator V belt should face the tensioner pulley.

·

Check that the fan and generator V belt is properly installed to each pulley.