2TR-FBE FUEL  SOLENOID VALVE(for Fuel Injection Volume Control)  INSPECTION  


PROCEDURE

Hide 1.INSPECT SOLENOID VALVE ASSEMBLY

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 18 to 28°C (64 to 82°F) 20 to 22 Ω
1 - Body ground Always 10 kΩ or higher
2 - Body ground


If the result is not as specified, replace the solenoid valve assembly.


b.

Check the operation of the solenoid valve assembly.

i.
A238192
1.719,1.177 1.844,1.323 0.125,0.146 10 false E 1.031,1.365 1.146,1.51 0.115,0.146 10 false F 1.167,1.542 1.365,1.75 0.198,0.208 10 false *a
*a Does Not Flow
V100135

Air


Check that air does not flow from port E to port F.


ii.
A238193
0.406,0.563 0.406,1.156 true 0.646,0.563 0.646,1.156 true 1.885,1.448 2.01,1.615 0.125,0.167 10 false E 1.156,1.656 1.271,1.823 0.115,0.167 10 false F 0.344,1.177 0.458,1.344 0.115,0.167 10 false 1 0.604,1.177 0.719,1.344 0.115,0.167 10 false 2
V100135

Air


Apply battery voltage across the terminals.


iii.

Check that air flows from port E to port F.

If the result is not as specified, replace the solenoid valve assembly.