Home › Engine / Hybrid System › 2KD-FTV EMISSION CONTROL › EGR VALVE(w/o DPF)
RM1840EF _51 Engine / Hybrid System _009583 2KD-FTV EMISSION CONTROL _0052274 EGR VALVE(w/o DPF) G

2KD-FTV EMISSION CONTROL  EGR VALVE(w/o DPF)  INSPECTION  


PROCEDURE

Hide 1.INSPECT ELECTRIC EGR CONTROL VALVE ASSEMBLY (w/ EGR Cooler)

a.
A246466C02
0.792,0.292 0.906,0.292 0.906,0.292 1.292,1.302 true 0.583,0.198 0.771,0.354 0.188,0.156 10 false *1
*1 Cap


Inspect the electric EGR control valve.

HINT:

Install a cap to block the other port.


i.

When a vacuum of 27 kPa (200 mmHg, 7.88 in.Hg) is applied to the diaphragm chamber, check that the shaft rises and that air flows out.


ii.

While maintaining the above conditions, check that there are no leaks and that the shaft stays in position.


iii.

Check that the valve does not have heavy carbon deposits and is not stuck.

If the result is not as specified, replace the electric EGR control valve.



b.

Inspect the EGR valve position sensor.

i.
A085764C02
1.781,1.094 1.781,1.792 true 2.5,1.781 2.5,1.698 2.5,1.698 2.104,1.083 true 1.667,1.844 1.885,1.99 0.219,0.146 10 false E2 2.375,1.854 2.615,2 0.24,0.146 10 false VC 0.146,0.125 0.333,0.323 0.188,0.198 10 false *a
*a Component without harness connected
(Electric EGR Control Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (VC) - 2 (E2) 20°C (68°F) 2.8 to 7.8 kΩ


If the result is not as specified, replace the electric EGR control valve assembly.



c.

Create a vacuum in the diaphragm chamber.

HINT:

Install a cap to block the other port.



d.
A246467C01
0.792,0.115 0.688,0.115 0.688,0.115 0.469,1.021 true 1.344,0.479 1.25,0.479 1.25,0.479 0.646,1.01 true 0.917,1.667 1.021,1.667 1.021,1.667 1.479,1.479 false 0.885,0.021 1.292,0.177 0.406,0.156 10 false EGLS 1.438,0.385 1.646,0.542 0.208,0.156 10 false E2 0.115,0.063 0.302,0.219 0.188,0.156 10 false *a 0.708,1.573 0.896,1.729 0.188,0.156 10 false *1
*1 Cap
*a Component without harness connected
(Electric EGR Control Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (EGLS) - 2 (E2) 20°C (68°F)
EGR valve is fully opened
2.0 to 7.0 kΩ
20°C (68°F)
EGR valve is fully closed
0.1 to 2.5 kΩ


HINT:

The resistance increases in proportion to the opening amount of the EGR valve.


If the result is not as specified, replace the electric EGR control valve assembly.


Hide 2.INSPECT ELECTRIC EGR CONTROL VALVE ASSEMBLY (w/o EGR Cooler)

a.
A302982

Inspect the electric EGR control valve.

i.

When a vacuum of 27 kPa (200 mmHg, 7.88 in.Hg) is applied to the diaphragm chamber, check that the shaft rises and air flows out.


ii.

While maintaining the above conditions, check that there are no leaks and that the shaft stays in position.


iii.

Check that the valve does not have heavy carbon deposits and is not stuck.

If the result is not as specified, replace the electric EGR control valve.



b.

Inspect the EGR valve position sensor.

i.
A085764C02
1.781,1.094 1.781,1.792 true 2.5,1.781 2.5,1.698 2.5,1.698 2.104,1.083 true 1.667,1.844 1.885,1.99 0.219,0.146 10 false E2 2.375,1.854 2.615,2 0.24,0.146 10 false VC 0.146,0.125 0.333,0.323 0.188,0.198 10 false *a
*a Component without harness connected
(Electric EGR Control Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (VC) - 2 (E2) 20°C (68°F) 2.8 to 7.8 kΩ


If the result is not as specified, replace the electric EGR control valve assembly.



c.

Create a vacuum in the diaphragm chamber.


d.
A099572C02
0.438,1.646 0.438,1.156 true 0.646,0.969 1.042,0.385 1.042,0.385 1.146,0.385 true 0.396,0.979 0.51,1.146 0.115,0.167 10 false 3 0.583,0.979 0.698,1.135 0.115,0.156 10 false 2 0.802,0.979 0.927,1.146 0.125,0.167 10 false 1 0.24,1.688 0.667,1.844 0.427,0.156 10 false EGLS 1.229,0.302 1.458,0.469 0.229,0.167 10 false E2 0.042,0.031 0.229,0.188 0.188,0.156 10 false *a
*a Component without harness connected
(Electric EGR Control Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (EGLS) - 2 (E2) 20°C (68°F)
EGR valve is fully opened
2.0 to 7.0 kΩ
20°C (68°F)
EGR valve is fully closed
0.1 to 2.5 kΩ


HINT:

The resistance increases in proportion to the opening amount of the EGR valve.


If the result is not as specified, replace the electric EGR control valve assembly.


Hide 3.INSPECT NO. 2 EGR VALVE ASSEMBLY (w/ EGR Cooler)

a.
A147245

When a vacuum of 53 kPa (400 mmHg, 15.7 in.Hg) is applied to the diaphragm chamber, check that the valve turns and air flows out.


b.

Maintaining the above conditions, check that there are no leaks and the valve does not return.


c.

Check that the valve does not have heavy carbon deposits and is not stuck.

If the result is not as specified, replace the No. 2 EGR valve.