Home › Engine / Hybrid System › 2KD-FTV EMISSION CONTROL › DIFFERENTIAL PRESSURE SENSOR › from 2012.04
RM1840EF _51 Engine / Hybrid System _009583 2KD-FTV EMISSION CONTROL _0052282 DIFFERENTIAL PRESSURE SENSOR A

2KD-FTV EMISSION CONTROL  DIFFERENTIAL PRESSURE SENSOR  INSTALLATION  


PROCEDURE

Hide 1.INSTALL DIFFERENTIAL PRESSURE SENSOR ASSEMBLY

a.
A258390
0.938,2.313 1.844,2.313 1.844,2.313 1.844,2.5 true 1.479,2.313 1.479,2.49 false 2.396,3.167 1.854,3.167 1.854,3.167 1.854,2.938 false 0.948,3.167 1.49,3.167 1.49,3.167 1.49,2.948 false 2.396,0.74 2.792,0.74 false 2.583,0.74 2.583,0.938 false 2.51,0.219 2.563,0.219 2.563,0.219 2.677,0.521 false 0.385,1.208 0.573,1.365 0.188,0.156 10 false *a 2.104,1.219 2.292,1.375 0.188,0.156 10 false *a 2.323,0.135 2.51,0.292 0.188,0.156 10 false *d 1.146,1.198 1.333,1.354 0.188,0.156 10 false *b 2.896,1.208 3.083,1.365 0.188,0.156 10 false *b 0.729,2.229 0.917,2.385 0.188,0.156 10 false *1 2.417,3.073 2.604,3.229 0.188,0.156 10 false *2 0.74,3.083 0.927,3.24 0.188,0.156 10 false *3 2.5,0.969 2.688,1.125 0.188,0.156 10 false *4 1.708,0.583 1.865,0.74 0.156,0.156 10 false *c
*1 Marking
*2 Green Paint Mark
*3 Orange Paint Mark
*4 New Clip
*a CORRECT
*b INCORRECT
*c 14.3 mm (0.562 in.) or less
*d Clip must not protrude past end of hose


Install 2 new clips, the No. 6 exhaust pipe air hose and No. 7 exhaust pipe air hose to the differential pressure sensor.

HINT:
·

Connect the air hoses so that the paint marks of the air hoses are as shown in the illustration.

·

Make sure the clips are as shown in the illustration.




b.

Install the differential pressure sensor with the nut.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


c.

for Pre-Runner:

Install the sensor bracket with the bolt.

Torque:
20 N*m (199 kgf*cm, 14 ft.*lbf)


d.

Connect the connector.


Hide 2.INSTALL NO. 1 FRONT FLOOR HEAT INSULATOR

a.

Install the No. 1 front floor heat insulator with the 3 nuts.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)