RM1840EF
_51
Engine / Hybrid System
_009585
2TR-FE EMISSION CONTROL
_0052304
PURGE VALVE
A
2TR-FE EMISSION CONTROL PURGE VALVE INSTALLATION
PROCEDURE
1.INSTALL PURGE VSV
a.
Install the purge VSV with the bolt.
- Torque:
- 9.0 N*m (92 kgf*cm, 80 in.*lbf)
b.
Connect the 2 purge line hoses to the purge VSV.
c.
Connect the purge VSV connector.