Home › Engine / Hybrid System › 1KD-FTV INTAKE / EXHAUST › INTAKE MANIFOLD(w/ Glow Plug Controller) › from 2012.04
RM1840EF _51 Engine / Hybrid System _009588 1KD-FTV INTAKE / EXHAUST _0052328 INTAKE MANIFOLD(w/ Glow Plug Controller) G

1KD-FTV INTAKE / EXHAUST  INTAKE MANIFOLD(w/ Glow Plug Controller)  INSPECTION  


PROCEDURE

Hide 1.INSPECT INTAKE MANIFOLD

NOTICE:
A271911

Do not adjust the adjusting screw or 2 swirl control valve actuator installation bolts.


a.

Check the operation of the swirl control valve.

i.

Check that the valve is fully opened under normal conditions.


ii.
A254203

for DPF:

Connect a vacuum pump to the control valve. Check that the valve is fully closed when a negative pressure of 35 kPa (263 mmHg, 10 in.Hg) is applied.


iii.

for i-ART:

Connect the vacuum pumps as shown in the illustration. First apply negative pressure to the diaphragm closer to the intake manifold. This will cause the actuator rod to move, which causes the swirl control valve to move. Then, apply negative pressure to the diaphragm on the outer side. This will cause the actuator rod to move further, which also causes the swirl control valve to move further. Check that the valve is fully closed when a negative pressure of 35 kPa (270 mmHg, 10 in.Hg) is applied.

A149795

HINT:

When applying negative pressure to the diaphragm on the outer side, the diaphragm closer to the intake manifold must be in a vacuum state.



iv.

Leave it for 1 minute and check that the vacuum pump needle does not move. If the result is not as specified, replace the intake manifold.